MDEK1001 Kit User Manual
© Decawave 2017
OP-MDEK1001-System-User-Manual-1.0
Page 35
7.
Next press the PC Enter key two times and the prompt below appears:
8.
Enter the command ‘nmt’ and press the return key
twice
which sets the tag into
Active mode
9.
Enter ‘les’ to display the location estimates of the tag
8.2 Example Output
In the example above, ‘08AF’ is an Anchor ID:
‘[0.5,0.5,1.97]’ is the Anchor coordinate for Anchor ‘08AF’ in the form of [x,y,z].
‘1.14’ is the estimated range between the Tag and Anchor ‘08AF’
‘est[1.05,1.04,1.15,92] ‘ is the estimated location of the Tag. In the form of
[x,y,z,quality factor]. (The quality factor is a measure of confidence of the accuracy
of the location estimate based on the ranges received)
8.3 Other Commands
Once tag is con
nected to tera term press ‘ ?’ and then the return key to obtain a list of the
executable commands. These commands are listed below.
Usage: <command> [arg0] [arg1] ...
Built-in commands:
** Command group: Base **
?: this help