CHAPTER 3: INSTALLATION INSTRUCTIONS
3-16
3.9 Electrical Connections
Fryers without built-in filtration do not require electrical connection. Fryer systems with built-in
filtration when installed must be electrically grounded in accordance with local codes, or in the
absence of local codes, with the appropriate national standards.
WARNING
Fryers with built-in filtration systems are equipped with a three-prong (grounding)
plug for protection against shock hazard. It should be plugged directly into a
properly grounded, three-prong receptacle. DO NOT CUT, REMOVE, OR
OTHERWISE BYPASS THE GROUNDING PRONG ON THIS PLUG.
For fryers with built-in filtration systems: The rating plate and wiring diagram are located on the
inside front door panel. Built-in filtration systems are equipped with 120VAC single-phase 60-hertz
system (Domestic), or 230VAC single-phase 50-hertz system (International/CE). Do not cut or
remove the ground prong from the power cord plug.
DANGER
This appliance requires electrical power (built-in filtration systems only) for
operation. Place the gas control valve in the OFF position in case of a prolonged
power outage. Do not attempt to operate this appliance during a power outage.