SUPER MARATHON SERIES GAS FRYERS
CHAPTER 3: INSTALLATION INSTRUCTIONS
3-10
3.6 Gas Inputs
CE UNITS ONLY:
A. Nominal Heat Inputs (Qn), Gas Type, Orifice Size, Part Number and Quantity/Color are listed in
the table below:
MODEL
NOMINAL HEAT INPUT-
Qn
(kW)
GAS TYPE
ORIFICE SIZE (MM)
ORIFICE
PART NO.
ORIFICE
QTY/ COLOR
SM 80 GM
37.5
G20
G25
G31
2.40
2.40
1.51
810-2060
810-2060
810-2059
5/BLUE
5/BLUE
5/RED
SM 60 GM
37.5
G20
G25
G31
2.40
2.40
1.51
810-2060
810-2060
810-2059
5/BLUE
5/BLUE
5/RED
SM 50 GM
30
G20
G25
G31
2.40
2.40
1.51
810-2060
810-2060
810-2059
4/BLUE
4/BLUE
4/RED
SM 35 GM
SM 40 GM
26
G20
G25
G31
2.40
2.40
1.51
810-2060
810-2060
810-2059
3/BLUE
3/BLUE
3/RED
SM 20 GM
15
G20
G25
G31
2.40
2.40
1.51
810-2060
810-2060
810-2059
2/BLUE
2/BLUE
2/RED
B. Adjustments for different gases are as follows:
MANIFOLD
GAS PRESSURE**
MODEL*
ORIFICE SIZE
(MM)
GAS TYPE
MBAR INCH
W.C.
BURNER
MARKING
PILOT
MARKING
SM 80 GM
2,40
2,40
1,51
2,40
(1)
G20
G25
G31
G25
(1)
10,0
15,0
27,0
10,0
(1)
4,0
6,0
10,8
4,0
(1)
Blue
Blue
Red
Blue
26N
26N
16LP
26N
SM 60 GM
2,40
2,40
1,51
G20
G25
G31
12,0
17,5
22,0
4,8
7,0
8,8
Blue
Blue
Red
26N
26N
16LP
SM 50 GM
2,40
2,40
1,51
G20
G25
G31
12,0
17,5
22,0
4,8
7,0
8,8
Blue
Blue
Red
26N
26N
16LP
SM 35 GM
SM 40 GM
2,40
2,40
1,51
G20
G25
G31
12,0
17,5
22,0
4,8
7,0
8,8
Blue
Blue
Red
26N
26N
16LP
SM 20 GM
2,40
2,40
1,51
G20
G25
G31
12,0
17,5
22,0
4,8
7,0
8,8
Blue
Blue
Red
26N
26N
16LP
*SM prefix- Super Marathon Series
*GM suffix- gas millivolt system with no electrical supply connections required
(1)
The Netherlands (NL) only.
NOTE: Outlet gas pressure must be adjusted strictly within the above requirements 5 to 10 minutes
after the appliance is operating.
** For controls and adjustments, please refer to the gas valve illustration on page 3-13. (Pilot Flame
Adjustment: Turn the pilot adjustment screw clockwise/counter-clockwise until the desired flame-
volume is achieved).
Содержание SM20 GM
Страница 43: ...THIS PAGE INTENTIONALLY LEFT BLANK...