background image

 

SUPER MARATHON SERIES GAS FRYERS 

CHAPTER 3:  INSTALLATION INSTRUCTIONS 

 

3-8 

3.4  Gas Connections (cont.) 

 

1.  CE ONLY: The following color codes indicate the type of gas to be used for each fryer and 

associated components. 

 

Gas Type 

CE Color Code 

Natural Blue 

Propane Red 

 
E.  Flexible Couplings, Connectors and Casters  

 

1.  If the fryer is to be installed with flexible couplings and/or quick-disconnect fittings, the 

installer must use a heavy-duty certified commercial flexible connector of at least 3/4" (22 
mm) NPT (with suitable strain-relief attachments), in compliance with local codes or in the 
absence of local codes, with the appropriate national or European Community (CE) 
standards.   Quick-disconnect devices must comply with local codes or in the absence of 
local codes, with the appropriate national or European Community (CE) standards.

 

 

2.  For an appliance equipped with casters, the installation shall be made with a connector that 

complies with local codes or in the absence of local codes, with the appropriate national or 
European Community (CE) standards.

 

 

3.  Under no circumstances are the connector and the quick-disconnect device, or its associated 

piping to be used to limit fryer movement. A restraining bracket is provided on the appliance 
back to prevent the unit from moving from its installed position. 

 

 WARNING  

Do not attach accessories to this fryer unless fryer is secured from tipping.  Personal injury 

may result. 

 

4.  To limit movement of the fryer, restraints independent of the flexible coupling or connector 

must be used.  Clips are located on the back panel of the fryer for the attachment of 
restraints. 

 

5.  If disconnection of the restraint is necessary, the restraint must be reconnected after the fryer 

has been returned to the position it was originally installed. 

 
F.  After hook up, bleed the gas line of air to ensure that the pilot light will ignite quickly and 

evenly. 

 

 WARNING 

Qualified personnel 

MUST

 perform any adaptation, modification, or gas conversion, if 

required.  Failure to use qualified personnel will void the Dean warranty. 

 

Содержание SM20 GM

Страница 1: ...rvice Association recommends using CFESA Certified Technicians 24 Hour Service Hotline 1 800 551 8633 DECEMBER 2003 PRINTED IN THE USA 8196001 NON CE Super Marathon Series Gas Fryers Installation Oper...

Страница 2: ...OF ITS AUTHORIZED SERVICE CENTERS AND OR THE PART BEING USED IS MODIFIED FROM ITS ORIGINAL CONFIGURATION THIS WARRANTY WILL BE VOID FURTHER FRYMASTER DEAN AND ITS AFFILIATES WILL NOT BE LIABLE FOR ANY...

Страница 3: ...spontaneously combust if left soaking in certain shortening material Additional information can be obtained in the filtration manual included with the system WARNING No structural material on the frye...

Страница 4: ...General 2 1 2 3 Principles of Operation 2 2 2 4 Rating Plate 2 2 2 5 Pre Installation 2 3 2 6 Equipment Installed at High Altitudes 2 4 2 7 Air Supply and Ventilation 2 5 2 8 Conversion of Units 2 6 3...

Страница 5: ...OPERATIONS 4 1 4 1 Initial Start up 4 1 4 2 Boil Out Procedure 4 4 4 3 Final Preparation 4 6 5 PREVENTATIVE MAINTENANCE 5 1 5 1 General 5 1 6 TROUBLESHOOTING 6 1 6 1 General 6 1 6 2 Pilot Burner Malfu...

Страница 6: ...1 2 Ordering Parts Customers may order parts directly from their local Authorized Parts Distributor For this address and phone number contact your maintenance and repair center or call the factory Th...

Страница 7: ...to personnel and which may cause damage to your system and or cause your system to malfunction 1 5 Service Personnel 1 5 1 Definitions A Qualified and or Authorized Operating Personnel 1 Qualified au...

Страница 8: ...ed by Dean to perform service on Dean equipment All authorized service personnel are required to be equipped with a complete set of service parts manuals and stock a minimum amount of parts for Dean e...

Страница 9: ...ely and file a concealed damage claim This should be done within 15 days of date of delivery Be sure to retain container and all packing materials for inspection NOTE Dean Does Not Assume Responsibili...

Страница 10: ...s and is mixed with air in the burners to create the correct ratio for proper combustion The mixture is ignited at the front end of each heat tube by the pilot light Internal diffusers slow the flame...

Страница 11: ...Series gas fryers operate on millivolts and do not require an external electric power supply unless equipped with a built in filtration system B Clearances The fryer area must be kept free and clear o...

Страница 12: ...s Association American Gas Association 55 Scarsdale Road 8501 E Pleasant Valley Road Don Mills ONT M3B 2R3 Cleveland OH 44131 National Electrical Code Canadian Electric Code c22 1 part 1 ANSI NFPA 70...

Страница 13: ...1000 F 427 538 C Check air movement during installation Strong exhaust fans in the exhaust hood or in the overall air conditioning system can produce slight air drafts in the room 4 Do not place the f...

Страница 14: ...ure 1 mbar 10 2 mm W C 0 4 inch W C 20 mbar 204 mm W C 8 inch W C 1 inch W C 25 4 mm W C 2 5 mbar Heat Input 1 kW 3410 BTU hr 100 BTU hr 0 0293 kW Temperature 0 Celsius 32 Fahrenheit Temperature in de...

Страница 15: ...avoid oil spills and the falls and severe burns that could occur This fryer may tip and cause personal injury if not secured in a stationary position 3 2 Leg and Caster Installation WARNING Dean fryer...

Страница 16: ...n the bolts to 50 inch lbs 5 65 Nm torque 3 3 Leveling the Fryer A Place a carpenter s level across the top of the fryer and level the unit front to back If the fryer is not level from side to side a...

Страница 17: ...ryer in an alcove battering to other appliances etc WARNING For caster retrofit the unit must be at room temperature and drained of shortening before installing the casters E Installing Optional Swive...

Страница 18: ...are detected the gas supply MUST be shut off at the main shut off valve The local gas company or FASC should be contacted immediately to rectify the problem 3 4 Gas Connections CE REQUIREMENTS Super M...

Страница 19: ...f PSI 3 45 kPa 35 mbar a step down regulator will be required DANGER Before connecting new pipe to this appliance the pipe must be blown out thoroughly to remove all foreign material Foreign material...

Страница 20: ...as odors are detected shut off the gas supply to the appliance at the main shut off valve and immediately contact the local gas company or an authorized service agency for service DANGER Dry firing yo...

Страница 21: ...inches W C 27 mbars gas pressure 2 Confirm that the arrow forged into the bottom of the regulator body which indicates gas flow direction is pointed downstream towards the fryers The air vent cap is a...

Страница 22: ...hat complies with local codes or in the absence of local codes with the appropriate national or European Community CE standards 3 Under no circumstances are the connector and the quick disconnect devi...

Страница 23: ...onnel Failure to use qualified personnel will void the Dean warranty DANGER This appliance was configured at the factory for a specific type of gas Converting from one gas type to another requires the...

Страница 24: ...IZE MM GAS TYPE MBAR INCH W C BURNER MARKING PILOT MARKING SM 80 GM 2 40 2 40 1 51 2 40 1 G20 G25 G31 G25 1 10 0 15 0 27 0 10 0 1 4 0 6 0 10 8 4 0 1 Blue Blue Red Blue 26N 26N 16LP 26N SM 60 GM 2 40 2...

Страница 25: ...T LP 2 80 35 1 70 51 810 2140 810 2064 3 3 SM 20 GM 50 NAT LP 2 18 44 1 40 54 810 2050 810 2324 2 2 B Adjustments for different gases are as follows Gas Adjustments Gas Type Natural LP Incoming Gas Su...

Страница 26: ...er and orifice location when performing the following conversions When converting from G20 to G25 gas the following procedures apply Equipment replacement is not required Adjust orifice gas pressure t...

Страница 27: ...can only be executed by qualified factory authorized personnel ON Button pilot gas flow OFF Button Pressure flow adjustment Thermocouple connection Pilot flow adjustment Vent tube connection Vessel As...

Страница 28: ...valve adjustment screw see page 3 11 for gas types and pressures After adjustment replace the adjustment screw cover Factory MUST be notified so the conversion can be documented and a new rating plat...

Страница 29: ...ee Section 3 6 for orifice quantities required for conversion Natural Gas to Propane Components Propane To Natural Gas Components REF DESCRIPTION REF DESCRIPTION 810 2400 Pilot orifice 16LP 810 0811 P...

Страница 30: ...gged directly into a properly grounded three prong receptacle DO NOT CUT REMOVE OR OTHERWISE BYPASS THE GROUNDING PRONG ON THIS PLUG For fryers with built in filtration systems The rating plate and wi...

Страница 31: ...mb screen covering the heating tubes Ensure the screws holding the thermostat and high limit control sensing bulbs into the frypot are tight WARNING Do not bang fry baskets or other utensils on the fr...

Страница 32: ...at the base of the frypot CE UNITS ONLY Ensure that the following steps are done in sequence before lighting or re lighting the pilot 1 Turn off the manual shut off valve on the incoming service line...

Страница 33: ...sary to meet local conditions and are to be performed only by qualified service personnel Adjustments are the responsibilities of the customer or dealer and are not covered by Dean warranty The pilot...

Страница 34: ...unit These units are not intended for this purpose and will be damaged by the solution DANGER Remove all drops of water from the frypot before filling with cooking oil or shortening Failure to do so w...

Страница 35: ...not allow water or boil out solution to drain into the filter pan The filter pump is not designed for water operation and will be irreparably damaged I Close the drain add fresh water without boil ou...

Страница 36: ...ng during the melting process shorten the ON cycle and lengthen the OFF cycle Smoke indicates potential scorching of the shortening which will shorten its useful life D Before starting operation turn...

Страница 37: ...mercial grade cleaner formulated to effectively clean and sanitize food contact surfaces Read the directions for use and precautionary statements before use Particular attention must be paid to the co...

Страница 38: ...spect any wiring and ensure all connections are tight and all wiring is in good condition Ensure all safety features i e drain safety switches reset switches etc are present and functioning properly V...

Страница 39: ...upply line and check for contamination blow out if necessary then reinstall B Pilot burner ignites but will not remain lit when gas valve manual knob is released Non CE or the pilot button is released...

Страница 40: ...ve the pressure regulator adjustment cover Use screwdriver to turn the adjusting screw for proper pressure Replace cover re check pressure and re install pressure regulator adjustment cover C Signs of...

Страница 41: ...PP TH NON CE UNITS ONLY Honeywell Millivolt Gas Valve Wiring Thermostat Operating Black Red Red Yellow Braided Orange Braided THERMOPILE Black Red Red Black Black Red Red TP TH TP TH Robertshaw Vent...

Страница 42: ...opile 807 3565 Thermocouple 812 1284 Thermostat Operating 807 1692 Knob Thermostat 816 0139 NON CE UNITS ONLY Commonly replaced parts in older Non CE Super Marathon Series gas fryers are Gas Valve Hon...

Страница 43: ...THIS PAGE INTENTIONALLY LEFT BLANK...

Страница 44: ...isiana 71135 1000 Shipping Address 8700 Line Avenue Shreveport Louisiana 71106 TEL 1 318 865 1711 FAX Parts 1 318 688 2200 FAX Tech Support 1 318 219 7135 Price 14 00 PRINTED IN THE UNITED STATES SERV...