Page
7
of
18
Chimney
The Dartmoor 5 and W5 models require a 125mm (5”) first length of flue then stepping up into a
minimum of 150mm (6”) liner. When using this stove with the smoke exempt air stop fitted the flue
liner can be reduced to 125mm (5”). We strongly advise a minimum diameter of 150mm (6”) flue liner
be fitted when possible. The installation of a flue liner is recommended.
The chimney height must meet current building regulations.
These stoves are
not
suitable to be used in a shared flue situation.
The chimney must be sound and the flue not too large in section. If the existing flue is too large, a
liner will have to be fitted to reduce this flue size.
When the chimney is warm the draw must not be lower than 12PA with the door closed. If there is
excess flue draught a flue stabilizer might have to be installed.
It is recommended that this stove is fitted with a flue liner, the baffle plates can be removed to
facilitate cleaning through the stove.
Hearth, Surround and Register Plate
The stove must stand on non-flammable material at least 12mm thick (1/2”). The hearth must extend a
minimum of 225mm in front of the firebox and 150mm to the sides. Due to some of the stove doors
being large we recommend that the hearth projects forward further than the above minimum, to help
prevent any ash on the door falling onto the floor when the stove door is opened.
If the stove is installed into a fire opening made of non-combustible materials, we recommend a
minimum of 150mm gap to the sides, 300mm above and 50mm behind the stove. For minimum
distances to combustible material see below.
The both the Dartmoor 5 and W5 must be installed on a constructional hearth if a base plate protector
is not fitted to the stove.
We recommend that any Dartmoor stove fitted onto a heat sensitive hearth such as slate or marble to
have a base plate protector fitted to help prevent the hearth cracking. The Huccaby and the Foxworthy
do not require further heat shielding. Do not store wood or flammable materials under any stove
including the Foxworthy and the Huccaby.
** Please note a single heat shield is fitted to the appliances as standard and therefore is
considered to be the back of the appliance. All distances to the rear must be taken from the back
of the nearest heat shield to the combustible materials directly behind the stove.
See diagrams on next page.
Stove Type
Minimum from
back of appliance
to combustibles
With spigot shield
fitted **
Minimum from
side of appliance
to combustibles **
Minimum from
back of appliance
to combustibles
with double heat
and spigot shield
fitted **
Corner
installation
Distance A
Dartmoor 5
Eco
150mm
550mm
-------------------------
-------
400mm
Dartmoor W5
Eco
200mm
350mm
50mm
175mm
Содержание Dartmoor 5E
Страница 17: ...Page 17 of 18...