background image

Page 

16

 of 

18

 

 

 

 
 

DM5/W5E issue 1. 21

st

 October 2019 

 

 

 

THE DEAN FORGE FABRICATION LTD STOVES GUARANTEE 

 

Dean Forge Fabrication Ltd offers a five-year guarantee which covers the main body of the 
stove for manufacturing defects. 
 
In the event of a manufacturing defect we will replace any defective part free of charge, labour 
cost excluded. 
 
This guarantee is invalid if the stove is not assembled, installed or operated as per these 
instructions or properly maintained or does not comply with current building regulations and 
any regional legislation in force at the time. 
 
Dean Forge Fabrication Ltd does not guarantee the onsite assembly, installation or operation 
of the stove.  Please seek advice from your supplier / installer for any relevant guarantees 
applicable to the installation. 
 
Dean Forge Fabrication Ltd will not be held liable for any consequential or incidental loss, 
damage or injury, however caused. 
 
Claims under this guarantee should be first made through your retailer. 
 
This guarantee is only applicable in the UK. 
 
Nothing in this guarantee shall affect your statutory rights. 
 

Exclusions 

 

The following consumable parts are not covered by this guarantee: - 
 
Fire grate, log retainer, baffle plate, fire bricks, glass panels and door seals. 
 
Paint is also excluded from the guarantee as it will eventually deteriorate due to the normal 
working of the stove. 
 
Your assistance is requested by filling in and returning the product Registration and Guarantee 
Form.  This will help maintain our records and assist us in identifying your stove in the unlikely 
event of any problem occurring and also when you need to order any spare parts. 

Содержание Dartmoor 5E

Страница 1: ...appliances for use in smoke control areas in England In Scotland and Wales this power rests with Ministers in the devolved administrations for those countries Separate legislation the Clean Air North...

Страница 2: ...the extractor fan could cause the stove not to function properly and pull dangerous fumes into the room This must be checked by a trained qualified engineer before using the stove We do not recommend...

Страница 3: ...ve push the lever down to open and up to close Tertiary air control slider C is used to open and shut the air through the back of the stove This slider must be pushed fully in push left towards the st...

Страница 4: ...ers in the fire bed add suitable kindling to prevent excessive smoke Fuel overloading The maximum amount of fuel specified in this manual should not be exceeded overloading can cause excess smoke The...

Страница 5: ...e room If this should happen shut all the stove air controls open the windows and vacate the room until the smoke has cleared At all times consider the safety of yourself and others before taking the...

Страница 6: ...the polystyrene transit blocks holding the baffles Check all the fire bricks and baffle plates are in place and have not moved or been damaged in transit Inside the stove packed with these instructio...

Страница 7: ...rd further than the above minimum to help prevent any ash on the door falling onto the floor when the stove door is opened If the stove is installed into a fire opening made of non combustible materia...

Страница 8: ...t make sure all the fire bricks and baffles plates are in place Particular attention must be taken when checking the top baffle plate is in place See diagram below The Top vermiculite baffle sits on a...

Страница 9: ...x fitted in the back or side of the fireplace to enable access to clean the chimney when the stove is installed without a liner If the chimney has been lined and cannot be swept through the stove an a...

Страница 10: ...n the room must be taken into account Please Note Extractor fans when operating in the same room or space as the appliance may cause problems Extra air venting must be in place to counteract this affe...

Страница 11: ...inless steel knob J off the riddle bar and hook the bar through the hole in the arm of the centre grate D making sure the riddle bar sits under the centre grate arm 3 Fit the centre grate D with the a...

Страница 12: ...or W5 Eco with Multi fuel kit installed Now you are ready to install the multi fuel kit 1 Bolt the two grate supports G by bolting them through the base holes each side Make sure the inside nut is adj...

Страница 13: ...uct Dartmoor wood and multifuel heating stove product range Steel bodied stove fitted with cast iron doors Supplied in various sizes to give a range of heat output options Are in conformity with the p...

Страница 14: ...Satisfies Dartmoor 5 STDFDA5E STDFFOHE STDFFOLE Co 13 0 Wood 0 08 Ancit 0 12 5Kw 82 1 Wood 5Kw 80 7 Ancit Dartmoor W5 STDFDAW5E STDFHUE co 13 0 Wood 0 11 Ancit 0 08 5Kw 83 1 Wood 5Kw 80 3 Ancit Relea...

Страница 15: ...iency Supplier s Name Model Energy Efficiency Class Energy Labelling of Local Space Heaters Dartmoor W5 Eco A 5 0 n a 72 1 82 1 Seasonal Space Efficiency Net Efficiency Supplier s Name Model Energy Ef...

Страница 16: ...aller for any relevant guarantees applicable to the installation Dean Forge Fabrication Ltd will not be held liable for any consequential or incidental loss damage or injury however caused Claims unde...

Страница 17: ...Page 17 of 18...

Страница 18: ...td Dean Prior Buckfastleigh Devon TQ11 0LS PRODUCT REGISTRATION Name Address Phone Number Suppliers Details Name Address Phone Number Installers Details Name Address Phone Number Date of Purchase Date...

Отзывы: