Page
10
of
18
Stove Performance
(MSF
– Manufactured smokeless fuel)
Pre
–
Lighting Check and Commissioning
Check all Building Regulations have been adhered to.
The baffle plates are in the right position.
A smoke test has been done to check the chimney is clear.
Take a flue draught reading and make sure it meets the requirements for the stove.
Data Plate
All stoves are numbered and performance marked on a data plate which is found on a swinging arm
located in the middle front at the base of the stove.
Air Vent
Under part J of building regulations an air vent of the appropriate size must be fitted for all stoves with
a kw rating of over 5kw.
In very air tight properties designed with air permeability less than or equal to 5.0 m3/ (h.m2) per
hour, an air vent will need to be fitted for all kilowatts.
When fitting air vents any other appliance fitted within the room must be taken into account.
Please Note:
Extractor fans when operating in the same room or space as the appliance may cause
problems. Extra air venting must be in place to counteract this affect.
Air vent inlet grills must not be inadvertently blocked.
Air vents must not be fitted in positions where they can be inadvertently covered up.
As from the 1
st
October 2010 a compliant Carbon Monoxide Alarm must be fitted
Operation
with the door open can cause excess smoke. The appliance must not be operated with the
appliance door left open except as directed in the instructions.
Appliance
Dartmoor 5 Eco
Foxworthy Eco
Dartmoor Baker 5 Eco
Dartmoor W5
Huccaby
Dartmoor W5 Baker Eco
Fuel
Wood
MSF
Wood
MSF
Total Efficiency
%
82.1
80.7
83.1
79.7
Nominal heat output
kW
5.0
5..0
5.0
5.0
Mean CO emission (at 13 % O
2
)
%
0.08
0.12
0.11
0.08
Mean flue gas temperature
ºC
250
269
249
261
Flue gas mass flow
g/s
4.0
3.9
3.8
3.4
Mean C
n
H
m
(at 13 % O
2
)
Nmg/m
3
108
55
92
21
Mean NOx (at 13 % O
2
)
Nmg/m
3
106
97
96
110
DIN Plus dust (at 13 % O
2
)
Nmg/m
3
24
26
10
18
Appliance weight
Содержание Dartmoor 5E
Страница 17: ...Page 17 of 18...