background image

Page 

17

 of 

18

 

 

 

 
 

 

                 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание Dartmoor 5E

Страница 1: ...appliances for use in smoke control areas in England In Scotland and Wales this power rests with Ministers in the devolved administrations for those countries Separate legislation the Clean Air North...

Страница 2: ...the extractor fan could cause the stove not to function properly and pull dangerous fumes into the room This must be checked by a trained qualified engineer before using the stove We do not recommend...

Страница 3: ...ve push the lever down to open and up to close Tertiary air control slider C is used to open and shut the air through the back of the stove This slider must be pushed fully in push left towards the st...

Страница 4: ...ers in the fire bed add suitable kindling to prevent excessive smoke Fuel overloading The maximum amount of fuel specified in this manual should not be exceeded overloading can cause excess smoke The...

Страница 5: ...e room If this should happen shut all the stove air controls open the windows and vacate the room until the smoke has cleared At all times consider the safety of yourself and others before taking the...

Страница 6: ...the polystyrene transit blocks holding the baffles Check all the fire bricks and baffle plates are in place and have not moved or been damaged in transit Inside the stove packed with these instructio...

Страница 7: ...rd further than the above minimum to help prevent any ash on the door falling onto the floor when the stove door is opened If the stove is installed into a fire opening made of non combustible materia...

Страница 8: ...t make sure all the fire bricks and baffles plates are in place Particular attention must be taken when checking the top baffle plate is in place See diagram below The Top vermiculite baffle sits on a...

Страница 9: ...x fitted in the back or side of the fireplace to enable access to clean the chimney when the stove is installed without a liner If the chimney has been lined and cannot be swept through the stove an a...

Страница 10: ...n the room must be taken into account Please Note Extractor fans when operating in the same room or space as the appliance may cause problems Extra air venting must be in place to counteract this affe...

Страница 11: ...inless steel knob J off the riddle bar and hook the bar through the hole in the arm of the centre grate D making sure the riddle bar sits under the centre grate arm 3 Fit the centre grate D with the a...

Страница 12: ...or W5 Eco with Multi fuel kit installed Now you are ready to install the multi fuel kit 1 Bolt the two grate supports G by bolting them through the base holes each side Make sure the inside nut is adj...

Страница 13: ...uct Dartmoor wood and multifuel heating stove product range Steel bodied stove fitted with cast iron doors Supplied in various sizes to give a range of heat output options Are in conformity with the p...

Страница 14: ...Satisfies Dartmoor 5 STDFDA5E STDFFOHE STDFFOLE Co 13 0 Wood 0 08 Ancit 0 12 5Kw 82 1 Wood 5Kw 80 7 Ancit Dartmoor W5 STDFDAW5E STDFHUE co 13 0 Wood 0 11 Ancit 0 08 5Kw 83 1 Wood 5Kw 80 3 Ancit Relea...

Страница 15: ...iency Supplier s Name Model Energy Efficiency Class Energy Labelling of Local Space Heaters Dartmoor W5 Eco A 5 0 n a 72 1 82 1 Seasonal Space Efficiency Net Efficiency Supplier s Name Model Energy Ef...

Страница 16: ...aller for any relevant guarantees applicable to the installation Dean Forge Fabrication Ltd will not be held liable for any consequential or incidental loss damage or injury however caused Claims unde...

Страница 17: ...Page 17 of 18...

Страница 18: ...td Dean Prior Buckfastleigh Devon TQ11 0LS PRODUCT REGISTRATION Name Address Phone Number Suppliers Details Name Address Phone Number Installers Details Name Address Phone Number Date of Purchase Date...

Отзывы: