1. IDENTIFICATION OF THE APPLIANCE
1.1 IDENTIFICATION PLATE
There is an identification plate at the back of the appliance that indicates model and serial number.
1.2 TABLE OF TECHNICAL SPECIFICATIONS
CLASSIC
TECHNICAL SPECIFICATIONS
um
F 450
F 6000
F 800
F 900/A900
External dimensions: LxDxH
cm
45x60x86
60x60x86
80x60x86
90x60x86/51
Heating plate: LxD
cm
31x45
48x45
68x45
74x45
Net weight/with packaging
kg
115/125
170/180
180/200
180/200
Required flue depression
mbar
0,12
0,12
0,12
0,12
Nominal thermal output
kw
5
7,5
10
10
Co at 13% O²
%
0,21
0,21
0,21
0,21
Mean flue gas temperature
°C
262
262
303
241
Flue gas mass flow
g/s
12
11,8
11,6
11,6
Efficiency
%
70
75,5
73
73
ECO
TECHNICAL SPECIFICATIONS
um
E60
E80
E90
External dimensions: LxDxH
cm
60x60x86
60x60x86
80x60x86
Heating plate: LxD
cm
48x45
68x45
74x45
Net weight/with packaging
kg
130/140
165/180
175/190
Required flue depression
mbar
0,12
0,12
0,12
Nominal thermal output
kw
6,5
9
9
Co at 13% O²
%
0,15
0,13
0,13
Mean flue gas temperature
°C
263
228
228
Flue gas mass flow
g/s
10,9
13,7
13,7
Efficiency
%
71
71
71
FLUE CONNECTION
Above
Ø 13 mm
Rear
Ø 14 mm
Side
Ø 14 mm
DOMINO
TECHNICAL SPECIFICATIONS
um
D6
D6maxi
D8
D8maxi
External dimensions: LxDxH
cm
60x60x86
60x60x86
80x60x86
80x60x86
Heating plate: LxD
cm
45x48
45x48
66x48
66x48
Net weight/with packaging
kg
180/195
180/195
195/215
195/215
Required flue depression
mbar
0,12
0,12
0,12
0,12
Nominal thermal output
kw
7,5
7,5
10
10
Co at 13% O²
%
0,09
0,09
0,12
0,12
Mean flue gas temperature
°C
261
261
293
293
Flue gas mass flow
g/s
10,6
10,6
14,9
14,9
Efficiency
%
75,5
75,5
72,5
72,5
Internal diameter
of test flue:
D = 150 mm
SAFETY RULES
RULES AND/OR INSTRUCTIONS MARKED WITH THIS
SYMBOL ARE ASSOCIATED WITH SAFETY!
The following rules and precautions help you to avoid the
risks associated with use of this appliance:
• the appliance must be installed according to the rules in
section 2.2 of this handbook;
• installation must be carried out in conformity with all rules at
the workplace, as well as with all domestic and European
regulations;
• make sure the flue is suitable before connecting the
cooker to it;
• it is strictly forbidden to use chemical products for lighting
the cooker – such as alcohol, oil, petrol, etc.;
•
do not put in too much fuel as this can produce excessive
heat and overheat the appliance, causing potential
damage;
• the cooking plate can reach high temperatures of up to
around 400 °C; be careful therefore and do not touch it
without appropriate protection – the same applies to the
other components such as the firebox and oven doors and
their respective handles, glass surfaces and the flue pipe;
• do not put any plastic bottles or spray cans on top or in the
immediate vicinity of the appliance (risk of fire and
explosion);
• warn children of the risks and keep them away from the
stove when it is in operation;
• place sheet metal protection on the floor under the fill
opening, especially if the floor is made of lino or wood;
• use only natural fuel such as: wood, blocks of compressed
wood and lignite briquettes;
• do not burn any plastics, treated wood (e.g. chipboard)
or textiles;
•
clean the flue on a regular basis.