27
De Gier B.V., Westlandseweg 9, 2291 PG WATERINGEN, THE NETHERLANDS,
Tel. +31 (0)174 292089, Email: [email protected], www.degierdrivesystems.com
Versie 1 – 2020 / 03 / 01
11. Inspection and maintenance
Inspection and maintenance tasks may only be carried out by qualified staff, see section 1. The KL300 itself is
maintenance free. The gearbox has lifetime lubrication. Changing the gear oil is unnecessary.
Maintenance intervals
Every 6 months
• Check if the plastic protective cover is mounted correctly and is free of any damages.
• Check the steel cable and steel cable connections. These parts may have under no circumstances have
any kind of mechanical damage.
• Check for increased noise level.
Every year
• Check and re-tighten mounting bolts.
• Check couplings for wear and corrosion;
• If present, lubricate chain couplings (oil viscosity 80 cST to 120 cST at 20°C);
• Backup power; check (if present) the functionality of the emergency backup power source;
• Check whether the endpositions are still correct. Adjust if necessary.
Risk of injury or death due to electrical or mechanical forces!
Before starting to work on the gearbox or related parts, always switch the power off at the master switch or
operating switch and lock it out with a padlock to prevent switching on again.
Spare parts and parts replacement
Parts may only be replaced by qualified staff. Always use original spare parts and original lubricants. For
product safety reasons, De Gier only supplies gearboxes, motors, covers and PCB’s as replacement parts. Gear
unit parts may only be replaced or repaired by an authorised service representative of De Gier.
Image
Description
Article no.
Protective cover replacement
including screws and seal.
SP.DL.KL300.01
Replacement PCB including screws
SP.KL300.PCB.01
Replacement motor and gearbox
KL300
SP.KL300.1.024.08.01