H O S T I N T E R F A C E
Data Device Corporation
DS-BU-67301B-G
1/14
70
Figure 30. Synchronous, Multiplexed Address 32-bit - Single-Word Memory Read
Timing
Figure 30 Notes:
1. When nSELECT is asserted (low), the
Total-AceXtreme®
is selected for this
data transfer. nSELECT must be asserted through the full transfer cycle, and
de-asserted high at the end of the transfer.
2. The CPU_WORD_EN[1:0] inputs are used to specify which 16-bit data
memory words are to be read for this transfer. If either or both these bits is ‘0’,
then the corresponding 16-bit word(s) will return a value of ‘0000’. These
inputs should be tied high if unused.
3. Unless the
Total-AceXtreme
command FIFO is full, CPU_nSTOP is not
asserted for memory accesses, and will remain high.
nDATA_RDY
CPU_DATA
CPU_WORD_EN[1:0]
RD_nWR
MEM_nREG
ADDR_LAT
nDATA_STRB
nSELECT
HOST_CLK
CPU_nSTOP
tOHZ
tCLK
tRDD
tRDD
Data
tALS
tSH
tSS
tCS
tCH
tALH
Address
tAH
tAS
tAS
tAS
tAS
tAH
tWait
tAH
tAH
tOH
tDD
tSHC
CPU_nLAST