T O T A L - A C E X T R E M E ® S I G N A L S
Data Device Corporation
DS-BU-67301B-G
1/14
117
Table 20. RT Address Signals
Signal Name
BALL
Pullup/
Pulldown
Description
RTAD4 (MSB) (I)
H14
50k Pullup
RT Address input.
If the RT ADDRESS SOURCE, of the RT_GCFG (RT Global Configuration)
Register, is programmed to logic "0", then the Total-AceXtreme RT address is
provided by means of these 5 input signals.
In addition, if RT ADDRESS SOURCE is logic "0", the source of RT address
parity is RTADP.
RTAD3 (I)
G12
50k Pullup
RTAD2 (I)
G10
50k Pullup
RTAD1 (I)
G13
50k Pullup
RTAD0 (LSB) (I)
G14
50k Pullup
RTADP (I)
H13
50k Pullup
Remote Terminal Address Parity.
This input signal must provide an odd parity sum with RTAD4-RTAD0 in order
for the RT to respond to non-broadcast commands. That is, there must be an
odd number of logic "1"s from among RTAD4-RTAD0 and RTADP.
RT_AD_LAT (I)
G11
50k Pullup
RT Address Latch.
Input signal used to control the Total-AceXtreme’s internal RT address latch.
If RT_AD_LAT is logic "0," then the Total-AceXtreme internal RT Address will
continuously track inputs RTAD4-RTAD0 and RTADP.
When a logic "1" level is applied to the RT_AD_LAT input, the Total-
AceXtreme internal RT address may be optionally latched under software
control.
If RT_AD_LAT transitions from logic ‘0’ to logic “1” while nMSTCLR is high, the
Total-AceXtreme RT address will be latched from inputs RTAD4-RTAD0 and
RTADP on this rising edge.
For single RT mode, to enable the Total-AceXtreme’s RT address to be
software programmable, RT_AD_LAT must be connected to logic ‘1’.
Table 21. Miscellaneous Signals
Signal Name
BALL
Pullup/
Pulldown
Description
TAG_CLK (I)
M13
50k Pullup
Time Tag Clock.
External clock that may be used to increment the Time Tag Register. This
option is selected when input ball TAG_ENABLE is logic ‘1’.
TAG_LOAD (I)
M12
50k Pullup
External Time Tag Load Pulse.
Loads 48-bit, Time Tag Counter with value from an internal register
TAG_ENABLE (I)
N13
50k Pullup
Time Tag Enable.
If this input is set to logic ‘1’, the 48-bit, internal Time Tag counter will be
enabled. A logic ‘0’ input disables the internal Time Tag counter.