B U I L T - I N T E S T
Data Device Corporation
DS-BU-67301B-G
1/14
26
ordering of the signals in the scan chain is defined in the BSDL file that is included in
the
Total-AceXtreme®
Development Kit.
Table 2. Supported JTAG Functions
JTAG Instruction
Instruction
Register
Value
Description
BYPASS
0b111
The BYPASS Instruction is used to allow data to connect directly from
JTAG_TDI pin to the JTAG_TDO pin.
Reserved
0b110
Reserved
Reserved
0b101
Reserved
USERCODE
0b100
The USERCODE specifies which version of the Total-AceXtreme is present.
0x000000FF denotes the BU-67301B0T0L-E02
Other values are reserved.
IDCODE
0b011
The IDCODE for the Total-AceXtreme is 0x0590003F
HIGHZ
0b010
Sets all the Outputs and Bidirectional Outputs to a high impedance state. The
HIGHZ can be used to determine excessive leakage current during the Total-
AceXtreme’s manufacturing phase.
SAMPLE/PRELOAD
0b001
The SAMPLE function provides the ability to capture the current state of the I/O
pins. The Preload allows for JTAG to preload the JTAG cells with values which
will not actually be loaded until the appropriate instruction (such as EXTEST) is
entered.
EXTEST
0b000
The EXTEST Instruction allows for a test vector to be applied from the
Boundary Scan Register to the external pins of the Total-AceXtreme.