10. When the Dispenser Lamp does not light up
1. There is a possibility of electric shock, make sure to start repairing after turning off the power.
2. The lamp is a incandescent bulb which generates high heat, make sure not to get burn.
How to check
Take off the S/W and measure its
resistance at both of its terminals.It
should be
∞Ω
and
∞Ω
when the S/W is
Close and Open respectively.
1)Only
∞Ω
is measured : S/W Short
2)Only
∞Ω
is measured : S/W Open
Is the lamp
filament broken?
Is the contact
of the lamp socket
normal?
Does the contact
of the lamp bimetal
on and off normally?
Replace Lamp
Check Socket/Replace
Does it operate normally
after a certain time?
Replace Bimetal/
Replace Door
Replace Dispenser Pad
Replace Dispenser S/W
Check wires
Check wires
Replace PCB Main/
Replace PCB Case Ass'y
Does the Dispenser
Pad work normally?
Does the Dispenser
S/W on and off
normally?
Is a voltage out
put at PCB Case
CN7
⑩
-
⑨
correct?
Is the connection
between CN6
⑩
-
⑨
and PCB Main
CN31
⑥
-
⑤
secure?
Is the PCB Main
CN31
⑥
-
⑤
circuit
normal?
Check Dispenser wiring and Check
&Repair the Lamp Socket
How to check
Measure the voltage at both of CN6
terminals.It should be 0V and 5V
when the S/W is Close and Open
respectively.
1) Only
∞Ω
is measured : S/W Short
2) Only
∞Ω
is measured : S/W Open
START
YES
YES
YES
YES
YES
YES
YES
YES
YES
NO
NO
NO
NO
NO
NO
NO
NO
Caution
BRANDSOURCE-SM(EN)
2007.1.23
10:32
AM
페이지65
Содержание RF48SS
Страница 1: ...THE DCS REFRIGERATOR SERVICE MANUAL MODEL RF48SS ...
Страница 15: ...16 122 104 140 158 203 142 4 213 6lb Actual Refrigerant Pipe 2 2 ...
Страница 21: ...22 Door Handle Fridge Door ...
Страница 54: ...55 5 1 How to run Test Mode AC115V DC160V AC115V 1 When the refrigerator is not turned on ...
Страница 56: ...57 3 When Defrost does not operate NO NO 23 54 63 ...
Страница 57: ...58 4 When error is detected by Self Diagnosis Sensor Error ...
Страница 58: ...59 5 When the alarm sound will not turn off ...
Страница 59: ...60 ...
Страница 60: ...61 6 When there is fault in the display and communication error ...
Страница 61: ...62 7 When Fan does not operate ...
Страница 62: ...63 8 When Fresh Island does not operate properly Only applied to Fresh Island Model ...
Страница 63: ...64 115V 115V 9 When F R Room Lamp does not light up ...
Страница 65: ...66 11 When Cover Ice Route Motor Geared Motor does not operate properly Caution ...
Страница 66: ...67 12 WhenWaterValvedoesnotoperate 115V ...
Страница 67: ...68 115V 115V 115V 13 WhenCRUSHEDorCUBEDdoesnotoperateproperly ...
Страница 69: ...70 9 WIRING DIAGRAM ...
Страница 71: ...72 10 2 PARTS DESCRIPTION SMPS INVERTER Convert AC inputs into DC voltages 5V 12V for the refrigerator control ...