49
Make sure to turn it off before disassembly. Rrisk of electric shock.
PART NAME
DESCRIPTION
FIGURE
F-Room
–Duct
①
Refer to the first three steps of the
F-Room Evaporator to pull the
upper duct out.
②
Refer to the F-Room –Interior
Lamp to remove the lamp cover.
③
Pull out the cover of the interior
lamp at both sides of the duct
from the lower side to take it apart.
And then, remove the 6 clamp
screws on the cold air distribution
duct to remove it.
Rail
(Common to
R-and
F-Room)
①
Refer to the drawer
disassembly to remove
drawers.
②
Remove the screws
indicated with the arrow
marks.
Fresh Island
–Thermister,
PCB, LED
Lamp
①
Refer to the drawer disassembly
to remove drawers.
②
Loosen the four clamp screws
indicated with the black arrow
marks and pull the housing off the
Fresh Island out to remove the
upper plate.
③
There is the Fresh Island
Thermister on the bottom of the
upper plate. Unscrew the 3 screws
to remove the cover off the sensor.
④
To replace LED lamp, you need
to replace the whole PCB board to
which the lamp is mounted.
Fresh Island
–LED
Display
①
Fresh Island –Refer to the first
two steps of the removal of
Thermister and LED Lamp to
disassemble the LED Display
cover by using a flat –blade
screwdriver as shown in the
photo, and remove the housing
inside to take the display out from
the retaining hook.
Fresh Island
–Damper
①
Remove the drawer,the upper
frame of Fresh Island and the
Fresh Island draw, and remove
the connecting duct. Then,after
removing the water tank and
the housing at the rear of Fresh
Island, disassemble the
connecting duct.
②
Remove the 6 screws that hold
the damper at the bottom of the
middle wall to remove the
Damper Ass’y.
3
3
Fresh Island
Heater
Fan
Damper
Light
1
LED Lamp
Sensor
Housing
2
1
2
Caution
Please be careful not to rip off when you remove the
cover of the Fresh Island by pulling it forward.
1
2
Duct
1
2
BRANDSOURCE-SM(EN)
2007.1.23
10:31
AM
페이지49
Содержание RF48SS
Страница 1: ...THE DCS REFRIGERATOR SERVICE MANUAL MODEL RF48SS ...
Страница 15: ...16 122 104 140 158 203 142 4 213 6lb Actual Refrigerant Pipe 2 2 ...
Страница 21: ...22 Door Handle Fridge Door ...
Страница 54: ...55 5 1 How to run Test Mode AC115V DC160V AC115V 1 When the refrigerator is not turned on ...
Страница 56: ...57 3 When Defrost does not operate NO NO 23 54 63 ...
Страница 57: ...58 4 When error is detected by Self Diagnosis Sensor Error ...
Страница 58: ...59 5 When the alarm sound will not turn off ...
Страница 59: ...60 ...
Страница 60: ...61 6 When there is fault in the display and communication error ...
Страница 61: ...62 7 When Fan does not operate ...
Страница 62: ...63 8 When Fresh Island does not operate properly Only applied to Fresh Island Model ...
Страница 63: ...64 115V 115V 9 When F R Room Lamp does not light up ...
Страница 65: ...66 11 When Cover Ice Route Motor Geared Motor does not operate properly Caution ...
Страница 66: ...67 12 WhenWaterValvedoesnotoperate 115V ...
Страница 67: ...68 115V 115V 115V 13 WhenCRUSHEDorCUBEDdoesnotoperateproperly ...
Страница 69: ...70 9 WIRING DIAGRAM ...
Страница 71: ...72 10 2 PARTS DESCRIPTION SMPS INVERTER Convert AC inputs into DC voltages 5V 12V for the refrigerator control ...