
31
Remarks
3) Defrost Function
1) F/R-Room Defrost depends on the accumulated comp-on time.
2) With the initial power on,defrost starts at the both rooms after 4 hour accumulated comp-on time.
3) Defrost cycle is changed automatically from MIN 5 hours to MAX 10 hours.
4) The defrost cycle depends on the ambient temperature,the frequency of F/R- Door open,and the duration of F/R-Door Open.
5) The Defrost Heater Off temperatures are compared using the temperature values of R-Defrost Sensor and F-Defrost
Sensor and they are as follows:
General Defrost Condition
Forced Defrost Function
Category
Fridge
All cases
Freezer
All cases
63
℉
(Refer to options)
54
℉
(Refer to options)
For A/S
4) ALARM Function
①
Button Touch Tone
1) When selecting each button on the Control Panel,the Button Touch Sound is heard.
2) In the case of pressing more than two buttons at the same time or pressing a wrong button,the sound will not be heard.
②
DOOR-OPEN Alarm
1) After 2 minutes of the F/R-Room is open,the alarm goes off.
2) If the door continues to be open after that,the alarm will be heard every 2 minutes cycle.
3) The alarm stops immediately when both of the F/R-Doors are closed.
BRANDSOURCE-SM(EN)
2007.1.23
10:31
AM
페이지31
Содержание RF48SS
Страница 1: ...THE DCS REFRIGERATOR SERVICE MANUAL MODEL RF48SS ...
Страница 15: ...16 122 104 140 158 203 142 4 213 6lb Actual Refrigerant Pipe 2 2 ...
Страница 21: ...22 Door Handle Fridge Door ...
Страница 54: ...55 5 1 How to run Test Mode AC115V DC160V AC115V 1 When the refrigerator is not turned on ...
Страница 56: ...57 3 When Defrost does not operate NO NO 23 54 63 ...
Страница 57: ...58 4 When error is detected by Self Diagnosis Sensor Error ...
Страница 58: ...59 5 When the alarm sound will not turn off ...
Страница 59: ...60 ...
Страница 60: ...61 6 When there is fault in the display and communication error ...
Страница 61: ...62 7 When Fan does not operate ...
Страница 62: ...63 8 When Fresh Island does not operate properly Only applied to Fresh Island Model ...
Страница 63: ...64 115V 115V 9 When F R Room Lamp does not light up ...
Страница 65: ...66 11 When Cover Ice Route Motor Geared Motor does not operate properly Caution ...
Страница 66: ...67 12 WhenWaterValvedoesnotoperate 115V ...
Страница 67: ...68 115V 115V 115V 13 WhenCRUSHEDorCUBEDdoesnotoperateproperly ...
Страница 69: ...70 9 WIRING DIAGRAM ...
Страница 71: ...72 10 2 PARTS DESCRIPTION SMPS INVERTER Convert AC inputs into DC voltages 5V 12V for the refrigerator control ...