18
※
Location:
①
Cluster Radiating Type: It releases heat through the pipes in the front right and left inside of
the refrigerator to release heat to all over the cabinet, which is good for heat radiation and
foamed with rigid urethane,
②
It is installed outside of the refrigerant (old-type).
③
It is gathered in the lower side of the refrigerant, and its heat is radiated forcibly by using the fan.
☞
It releases the residual heat of condensation until it is completely liquefied, and makes the
gas change only its state without changing its temperature.
◆
References
◆
※
Thickness of the Pipe
①
Low Pressure: 0.25”
②
High Pressure: 0.19”
③
Capillary Tube: 0.016~0.03” or so
※
Length of the Condenser (300L for a Standard): 86.9’
①
AUXILIARY: 16.4’
②
HOT – PIPE: 21.6’
③
CLUSTER – PIPE: 49.2’
■
Capillary Tube
1. Roles: It decompresses the liquid refrigerant of room temperature and high pressure to
make the refrigerant of low temperature and pressure and supplies it to the evaporator.
1) It vaporizes the liquid more at low temperature during its evaporation.
2) Though the compressor stops working, the refrigerant does not flow backward to the
condenser but it flows into the evaporator. This makes small the pressure difference
between the high pressure side and the low pressure side, and it makes it easy to operate
the compressor again.
2. Overview
1) Diameter: 0.016”~0.03 or so
2) Length: It is possible to bring it into low temperature and pressure (50
℉
, 71.2lb/
㎡
) according to
the resistance of 6.56’ long and thin wall of the copper pipe.
■
Evaporator
1. Roles: It makes food frozen when the low pressure liquid refrigerant from the capillary tube
changes into the low pressure gas refrigerant by absorbing the compartment’s heat.
2. Principle: The liquid refrigerant of low temperature, which flows in from the evaporator,
keeps evaporating until it is completely gasified, and takes the residual heat of evaporation
away from the surrounding.
3. Types
1) Roll – Bond Condenser °ÊDirect Cooling One-Door Type
☞
It rolls and bonds two sheets of aluminum to make a passage for refrigerants.
2) Pin – Pipe Type °ÊIndirect Cooling Two-Door Type
☞
It attaches small-size aluminum sheets on aluminum pipe to achieve good cooling effect.
■
Compressor
1. Roles: It plays the same role as a pump which draws underwater from the earth. It takes
in the gas refrigerant with low temperature and pressure from the evaporator to change it
into the liquid refrigerant with high temperature and pressure in the compressor before
being sent to the condenser.
BRANDSOURCE-SM(EN)
2007.1.23
10:31
AM
페이지18
Содержание RF48SS
Страница 1: ...THE DCS REFRIGERATOR SERVICE MANUAL MODEL RF48SS ...
Страница 15: ...16 122 104 140 158 203 142 4 213 6lb Actual Refrigerant Pipe 2 2 ...
Страница 21: ...22 Door Handle Fridge Door ...
Страница 54: ...55 5 1 How to run Test Mode AC115V DC160V AC115V 1 When the refrigerator is not turned on ...
Страница 56: ...57 3 When Defrost does not operate NO NO 23 54 63 ...
Страница 57: ...58 4 When error is detected by Self Diagnosis Sensor Error ...
Страница 58: ...59 5 When the alarm sound will not turn off ...
Страница 59: ...60 ...
Страница 60: ...61 6 When there is fault in the display and communication error ...
Страница 61: ...62 7 When Fan does not operate ...
Страница 62: ...63 8 When Fresh Island does not operate properly Only applied to Fresh Island Model ...
Страница 63: ...64 115V 115V 9 When F R Room Lamp does not light up ...
Страница 65: ...66 11 When Cover Ice Route Motor Geared Motor does not operate properly Caution ...
Страница 66: ...67 12 WhenWaterValvedoesnotoperate 115V ...
Страница 67: ...68 115V 115V 115V 13 WhenCRUSHEDorCUBEDdoesnotoperateproperly ...
Страница 69: ...70 9 WIRING DIAGRAM ...
Страница 71: ...72 10 2 PARTS DESCRIPTION SMPS INVERTER Convert AC inputs into DC voltages 5V 12V for the refrigerator control ...