36
Details of Self-Diagnosis Light Display by Position
No
Items
DISPLAY LED
Trouble shooting
Remarks
1
2
3
4
5
6
7
8
9
10
11
12
13
14
R-SENSOR
R-DEFROST SENSOR
R-FAN ERROR
FRESH-SENSOR
R-DEFROST ERROR
AMBIENT TEMPERATURE SENSOR
F-SENSOR
F-DEFROST SENSOR
F-FAN ERROR
C-FAN ERROR
F-DEFROST ERROR
MAIN_LOAD ERROR
MAIN_PANEL ERROR
DAMPER HEATER ERROR
FRIDGE
SEGMENT
FRIDGE
SEGMENT
FREEZER SEGMENT
FREEZER SEGMENT
FREEZER SEGMENT
FREEZER SEGMENT
FREEZER SEGMENT
FREEZER SEGMENT
FREEZER SEGMENT
FREEZER SEGMENT
FRIDGE
SEGMENT
FRIDGE
SEGMENT
FRIDGE
SEGMENT
FRIDGE
SEGMENT
Sensor Housing slip-out from the
R-Room,Contact Failure,Wire Cut,Wire
Short,Defective R-Sensor.
Defrost Sensor Housing slip-out from the
evaporator of R-Room, Contact Failure,Wire
Cut, Wire Short,Defective Sensor.
Errors in operation of R-FAN
Motor,Contact failure of feedback
signal wire,no motor wire.
Fresh-Sensor Housing slip-out,Contact
Failure, Wire Cut,Wire Short,
Defective Fresh-Sensor.
R-Heater Housing slip-out,Contact Failure,Wire
Cut, Wire Short,Defective R-Heater,Defective
Defrost Temp Fuse.
Ambient Temperature Sensor Housing slip-out,
Contact Failure,Wire Cut, Wire Short,Defective
Ambient Temperature Sensor.
Sensor Housing slip-out from the F-
Room,Contact Failure,Wire Cut,Wire
Short,Defective F-Sensor.
F-Defrost Sensor slip-out from the evaporator of
the F-Room,Contact Failure, Wire Cut,Wire
Short, Defective Sensor.
Errors in operation of F-FAN
Motor,Contact failure of feedback
signal line,no motor wire,etc.
Errors in operation of C- FAN
Motor,Contact failure of feedback
signal line,no motor wire.
F-Heater Housing slip-out, contact
failure,wire cut,wire short,Defective
F-Heater,Defective Defrost Temp Fuse.
Defective Main PCB Pattern and
MICOM
Defective PCB,Housingslip-out,Contact
Failure, Wire Cut, Wire Short, Defective
MICOM.
Displaying a defect when the R-
Sensor temp is over 149
℉
(65
℃
)
or below -58
℉
(-50
℃
).
Displaying a defect when the R-
Defrost Sensor temp is over 149
℉
(65
℃
) or below -58
℉
(-50
℃
).
Displaying a defect when F.G signals
generated during operation of FAN-
Motor are not input.
Displaying a defect when the
Fresh- Sensor temp is over 149
℉
(65
℃
). or below -58
℉
(-50
℃
).
Displaying a defect when the R-
Defrost completes automatically in
50 minutes.
Displaying a defect when the Ambient
Temperature Sensor temp is over 149
℉
(65
℃
) or below -58
℉
(-50
℃
).
Displaying a defect when the F-
Sensor temp is over 149
℉
(65
℃
)
or below -58
℉
(-50
℃
).
Displaying a defect when the temp
sensing of the F-Defrost Sensor is
over 149
℉
(65
℃
) or below -58
℉
(-50
℃
).
Displaying a defect when the F .G
signals generated during operation
of FAN-Motor are not input.
Displaying a defect when the F .G
signals generated during operation
of FAN-Motor are not input.
Displaying a defect when
F-Defrost completes automatically
in 50 minutes.
Displaying a defect when errors
occur between main MICOM and
load MICOM
Displaying a defect when errors
occur between main MICOM and
panel MICOM
Defective PCB,Housingslip-out,Contact
Failure, Wire Cut, Wire Short, Defective
MICOM.
Displaying a defect when errors
occur between main MICOM and
panel MICOM
BRANDSOURCE-SM(EN)
2007.1.23
10:31
AM
페이지36
Содержание RF48SS
Страница 1: ...THE DCS REFRIGERATOR SERVICE MANUAL MODEL RF48SS ...
Страница 15: ...16 122 104 140 158 203 142 4 213 6lb Actual Refrigerant Pipe 2 2 ...
Страница 21: ...22 Door Handle Fridge Door ...
Страница 54: ...55 5 1 How to run Test Mode AC115V DC160V AC115V 1 When the refrigerator is not turned on ...
Страница 56: ...57 3 When Defrost does not operate NO NO 23 54 63 ...
Страница 57: ...58 4 When error is detected by Self Diagnosis Sensor Error ...
Страница 58: ...59 5 When the alarm sound will not turn off ...
Страница 59: ...60 ...
Страница 60: ...61 6 When there is fault in the display and communication error ...
Страница 61: ...62 7 When Fan does not operate ...
Страница 62: ...63 8 When Fresh Island does not operate properly Only applied to Fresh Island Model ...
Страница 63: ...64 115V 115V 9 When F R Room Lamp does not light up ...
Страница 65: ...66 11 When Cover Ice Route Motor Geared Motor does not operate properly Caution ...
Страница 66: ...67 12 WhenWaterValvedoesnotoperate 115V ...
Страница 67: ...68 115V 115V 115V 13 WhenCRUSHEDorCUBEDdoesnotoperateproperly ...
Страница 69: ...70 9 WIRING DIAGRAM ...
Страница 71: ...72 10 2 PARTS DESCRIPTION SMPS INVERTER Convert AC inputs into DC voltages 5V 12V for the refrigerator control ...