Make Connections as follows:
1. Connect the terminal marked “+” to 9 -
power source.
2. Connect the terminal marked “-” to the
power supply ground.
3. Connect the terminal marked “GND” to the
chassis ground. This must be a good ground to the
engine block or heads. An improper ground will
immediately cause the unit to fail!
It is highly recommended that the ground be
checked w/ an ohm meter to verify a good
connection. A reading of more than 1-2 ohms
between the “GND” terminal and the magneto body
will cause failure!
4. Connect the terminal marked “KILL” to the
NEG Coil Terminal.
WARNING-HIGH VOLTAGE !!
Failure to properly handle and insulate connection
could result in electrical shock!
7
Davis Technologies TMS-5500-SL Elec Points
www.moretraction.com