Confirming Settings
The current setting for the different adjustments can
be verified at any time using the Test button and the
LED. This process is divided into 2 sections.
Standard, Advanced and Mag. The different sections
are chosen by the position by the dial when the
verification is started.
Standard
values can be verified at any time by
following these steps.
1.
Turn the power “On”
2.
Set “M” dial any position from 1-7.
3.
Press the “Test” button and HOLD
DOWN.
4.
The LED will glow solid for 8
seconds (as in the Forced Activation Test),
then blink to show the firmware version.
5.
Next the LED will flash the value for the Buffer.
(A setting of zero is indicated by a short blip of
the LED).
6.
After a short pause, the Led will flash for the
value of Sample Rate, followed by a pause.
8.
Lastly, the LED will Flash the current Self
Learning status value.
(for tech support
purposes only).
23
Davis Technologies TMS-5500-SL Elec Points
www.moretraction.com
Содержание TMS-5500-SL
Страница 32: ...This Page Left Blank 30 Davis Technologies TMS 5500 SL Elec Points www moretraction com ...
Страница 35: ...Main Tab Basic Screen 33 Davis Technologies TMS 5500 SL Elec Points www moretraction com ...
Страница 37: ...More Tab Settings 35 Davis Technologies TMS 5500 SL Elec Points www moretraction com ...
Страница 39: ...More Tab Advanced Settings 37 Davis Technologies TMS 5500 SL Elec Points www moretraction com ...
Страница 41: ...Admin Tab 39 Davis Technologies TMS 5500 SL Elec Points www moretraction com ...
Страница 46: ...Notes 44 Davis Technologies TMS 5500 SL Elec Points www moretraction com ...
Страница 48: ......