Testing
After installation it is recommended that you test the
system. To do so please follow these instructions
step by step
.
Forced Activation Test:
This test is useful to check both stages of retard.
1.
Set the “M” dial to any setting between 1 to 7.
2.
Connect a timing light to the engine
3.
Turn “on” the power to the unit, the LED should
begin to flash.
4.
Start the engine.
5.
With the engine idled up to about 3500 rpm;
press the Test button on the unit until the LED
glows solid. The first timing retard stage will
activate for 4 seconds, then the second stage
for the next 4 seconds.
Note: After the test is complete, the LED will blink to
show the firmware version.
9
Davis Technologies TMS-5500-SL Elec Points
www.moretraction.com