SELF-DIAGNOSTIC ERROR CODES

The Spa Power 500A Mk2 controller has extensive self diagnostic capabilities. In the event 

of  a problem it will indicate an error number according to the nature of the problem. The 

error numbers & their meanings are listed below. Note: When in an error state the alarm 

can be muted by pushing the AIR/AUX button. 

Error 1 (H20) - 

Prime Failed

This is not necessarily a problem with the SP500A Mk2 itself, but indicates that no water 

is being detected in the heaters housing. Prime failed is a special case in that it can be 

recovered from by pushing a button. A push of the pump button will run the pump for 10 

seconds to try to get water to the heater. If successful normal operation will resume. If 

unsuccessful, Error 1 (H20) will be indicated on the display again. 

With any Error 3 - 5, 7 - 8, spa operation will stop & not continue until the controller 

is reset. The controller can only be reset by pushing the UP,DOWN & PUMP buttons 

simultaneously. 
The controller will remain in an error condition 

even when reset at mains power, controller 

will only continue normal operation after 

the UP, DOWN & PUMP buttons are pushed 

simultaneously (see below). 

Error 3 - 

Stuck Button

This error indicates that one of the buttons in the touchpad is stuck or has been held down 

for more than one minute. This may be caused by the pool cover pressing on the touchpad 

or by water getting into the touchpad or by damage to the touchpad or its cable. Try to 

reset the spa. If there is still a problem then contact your spa pool supplier. 

Error 4 - 

No Water Sensor

This error indicates a problem with the optical water sensor in the heater. The problem may 

be caused by the sensor being disconnected or by damage to the sensor. Try to reset the 

spa. If there is still a problem then contact your spa pool supplier. 

Error 5 - 

Overtemperature

This error indicates that the digital temperature sensor in the heater or pool has detected 

a temperature of 45

°

C or more. This may not be a problem with the SP500A Mk2, it may 

be caused by excessive pump use in hot weather, or pump failure. Turn off the spa & allow 

time for the water to cool. If there is still a problem contact your spa pool supplier. 

Error 6 - 

Please call service for assistance.

Error 7 - 

Stuck Relay

This error indicates a problem with the heater control circuitry inside the unit. Contact your 

spa pool supplier. 

Error 8 - 

No Temperature Data

This error indicates a problem with the digital temperature sensor in the heater or pool wall 

or that both the in heater & in pool sensors are connected. Check that only one sensor is 

connected & that it has not become disconnected or damaged. Try to reset the spa. If there is 

still a problem then contact your spa pool supplier. 

Содержание SpaPower SP500

Страница 1: ...ent protection devices Rated residual operating current not exceeding 30mA WARNING This appliance is not intended for use by young children or infirm persons without supervision Young children should be supervised to ensure they do not play with the appliance WARNING The product must be covered by an enclosure having a degree of protection to IP24 or better to prevent water ingress If the supply c...

Страница 2: ...rature will be maintained very close to the set temperature Sensed Temperature The sensed temperature in the heater can be checked if necessary by pressing the Up Down buttons simultaneously The display flashes while showing the sensed temperature Heating Mode Selection In addition to the temperature setting the user can select the preferred heating mode The two available heating modes are 1 Deman...

Страница 3: ...n the touch pad whenever the system is in full automatic control mode In this mode the system automatically activates the pump heater to filter the water maintain the set water temperature If this light is flashing the water sensor is not detecting any water Pump Light The GREEN Pump indicator light will appear on the touchpad whenever the pump is running in both auto manual use mode Heater Light ...

Страница 4: ...ean up cycle can be initiated to filter the water after the spa pool has been used This is done by simply pushing the Pump Button to leave Auto Mode switch on the pump This will circulate the water through the filter for 90 minutes After 90 minutes the system will return to Auto Mode maintain the temperature ready for the next time the spa pool is used Adjusting Minimum Filtration Time First push ...

Страница 5: ...heat out Also make sure the spa is shaded from direct sunlight Do not operate your water heater in ambient temperatures over 40 C WARNING Before using ensure that the spa pool has been connected to a suitable weather protected outlet socket equipped with a double pole isolating switch which is of the correct rating and complies with the local wiring regulations When installing refer to your local ...

Страница 6: ...r has been held down for more than one minute This may be caused by the pool cover pressing on the touchpad or by water getting into the touchpad or by damage to the touchpad or its cable Try to reset the spa If there is still a problem then contact your spa pool supplier Error 4 No Water Sensor This error indicates a problem with the optical water sensor in the heater The problem may be caused by...

Страница 7: ...ater element thermostat pockets High pH will cause scale formation cloudy water Total Alkalinity This is a measure of how resistant your spa water is to change of pH A low TA 0 80 ppm will allow the pH to fluctuate rapidly normally to the acid end will make it very hard to correct the pH back to the ideal range Chlorine Levels of sanitiser are important to prevent the build up of bacteria algae in...

Страница 8: ...sed by Davey on the basis of their product knowledge and reasonable judgement and will be accepted if a relevant defect is found the warranty claim is made during the relevant warranty period and none of the excluded conditions listed above apply The customer will be notified of the warranty decision in writing and if found to be invalid the customer must organise collection of the product at thei...

Отзывы: