4

AUTO SANITISING (FILTRATION)

The Spa Power 500A Mk2 automatically maintains the filtration/sanitation of the spa 

pool water. The minimum amount of filtration time is programmable by the user & can be 

adjusted between 0 & 15 minutes per hour (0 to 6 hours per day). In order to maintain 

correct filtration of the pool water, the SP500A Mk2 monitors the time for which the pump 

runs in normal pool operation. If the pump has only run for a short time, the system will 

automatically run the pump for an additional period every hour to reach the minimum 

filtration time set by the user. 

AUXILIARY AIR BUTTON

The Air button controls an auxiliary air blower (or water pump). It is used to turn the blower 

on & off. Two pushes of the air button cycles the blower as follows: 

Clean Up Cycle

If desired a clean up cycle can be initiated to filter the water after the spa pool has been 
used. This is done by simply pushing the Pump Button 

 to leave Auto Mode & switch 

on the pump. This will circulate the water through the filter for 90 minutes. After 90 minutes 
the system will return to Auto Mode & maintain the temperature ready for the next time the 
spa pool is used. 

Adjusting Minimum Filtration Time

First push the Down 

 & Air/Aux 

 buttons together to display the filtration time 

setting on the digital readout.  

The default setting is 10 minutes per hour (= 4 hours per day). Holding down the Up Button 

 or Down Button 

 will adjust the filtration time setting between 0 & 15 minutes 

per hour (= 0 to 6 hrs per day).

Push 1 - Blower ON

Push 2 - Blower OFF

Note: If left on, this accessory will automatically switch off after 20 minutes. If the heater element is on, 

switching on this accessory may cause the heater to loadshed & switch off. This is to keep the total 

power load to a safe level. 

Air Blower or Auxiliary Pump

Содержание SpaPower SP500

Страница 1: ...ent protection devices Rated residual operating current not exceeding 30mA WARNING This appliance is not intended for use by young children or infirm persons without supervision Young children should be supervised to ensure they do not play with the appliance WARNING The product must be covered by an enclosure having a degree of protection to IP24 or better to prevent water ingress If the supply c...

Страница 2: ...rature will be maintained very close to the set temperature Sensed Temperature The sensed temperature in the heater can be checked if necessary by pressing the Up Down buttons simultaneously The display flashes while showing the sensed temperature Heating Mode Selection In addition to the temperature setting the user can select the preferred heating mode The two available heating modes are 1 Deman...

Страница 3: ...n the touch pad whenever the system is in full automatic control mode In this mode the system automatically activates the pump heater to filter the water maintain the set water temperature If this light is flashing the water sensor is not detecting any water Pump Light The GREEN Pump indicator light will appear on the touchpad whenever the pump is running in both auto manual use mode Heater Light ...

Страница 4: ...ean up cycle can be initiated to filter the water after the spa pool has been used This is done by simply pushing the Pump Button to leave Auto Mode switch on the pump This will circulate the water through the filter for 90 minutes After 90 minutes the system will return to Auto Mode maintain the temperature ready for the next time the spa pool is used Adjusting Minimum Filtration Time First push ...

Страница 5: ...heat out Also make sure the spa is shaded from direct sunlight Do not operate your water heater in ambient temperatures over 40 C WARNING Before using ensure that the spa pool has been connected to a suitable weather protected outlet socket equipped with a double pole isolating switch which is of the correct rating and complies with the local wiring regulations When installing refer to your local ...

Страница 6: ...r has been held down for more than one minute This may be caused by the pool cover pressing on the touchpad or by water getting into the touchpad or by damage to the touchpad or its cable Try to reset the spa If there is still a problem then contact your spa pool supplier Error 4 No Water Sensor This error indicates a problem with the optical water sensor in the heater The problem may be caused by...

Страница 7: ...ater element thermostat pockets High pH will cause scale formation cloudy water Total Alkalinity This is a measure of how resistant your spa water is to change of pH A low TA 0 80 ppm will allow the pH to fluctuate rapidly normally to the acid end will make it very hard to correct the pH back to the ideal range Chlorine Levels of sanitiser are important to prevent the build up of bacteria algae in...

Страница 8: ...sed by Davey on the basis of their product knowledge and reasonable judgement and will be accepted if a relevant defect is found the warranty claim is made during the relevant warranty period and none of the excluded conditions listed above apply The customer will be notified of the warranty decision in writing and if found to be invalid the customer must organise collection of the product at thei...

Отзывы: