CONGRATULATIONS

Congratulations on choosing the latest SpaPOWER 500A Mk2 control system. This 

controller makes use of the latest technology, including innovative optical & digital sensor 

designs. The user friendly touchpad & reliable components provide you with the best 
value controller in its class.

 

TEMPERATURE CONTROL

The SpaPOWER 500A Mk2 automatically controls the pump & heater to filter the water & 

maintain it at the desired temperature as set by the user (see below). The user can leave the 

system to look after the spa & know it will be at the correct temperature whenever he or she 

wants to use it.

 

Adjusting Set Temperature

The SpaPOWER 500A Mk2 gives the user direct control of the pool temperature from the 

poolside control panel. Holding down the Up or Down button will adjust the temperature set 

point as shown on the digital readout. There is a slight delay before the buttons operate to 

reduce the risk of accidental adjustment. The pool temperature will be maintained very close 

to the set temperature.

 

Sensed Temperature

The sensed temperature (in the heater) can be 

checked if necessary by pressing the Up & Down 

buttons simultaneously. The display flashes while 

showing the sensed temperature. 

Heating Mode Selection

In addition to the temperature setting the user can select the preferred heating mode. The two 

available heating modes are....
1. Demand Heating (displayed as Ht.d). This is the default setting in which the pump & heater 

will come on automatically whenever the temperature drops slightly below the set point. 

2. Filtration Only Heating (displayed as Ht.F). In this mode the pump & heater will come on 

automatically no more than once per hour to filter & heat the water. This mode is provided as 

an option for those who prefer to limit the natural cycling of the system. 

To select the heating mode first press the Pump & Down buttons simultaneously to display the 

current heating mode, then press & hold the Up or Down buttons to change modes. 

Increase the set temperature by 0.5

°

C per beep (Max = 41.5

°

C)

UP

DOWN

Default Display = Temperature Set Point

Decrease the set temperature by 0.5

°

C per beep (Min = 10

°

C)

Содержание SpaPower SP500

Страница 1: ...ent protection devices Rated residual operating current not exceeding 30mA WARNING This appliance is not intended for use by young children or infirm persons without supervision Young children should be supervised to ensure they do not play with the appliance WARNING The product must be covered by an enclosure having a degree of protection to IP24 or better to prevent water ingress If the supply c...

Страница 2: ...rature will be maintained very close to the set temperature Sensed Temperature The sensed temperature in the heater can be checked if necessary by pressing the Up Down buttons simultaneously The display flashes while showing the sensed temperature Heating Mode Selection In addition to the temperature setting the user can select the preferred heating mode The two available heating modes are 1 Deman...

Страница 3: ...n the touch pad whenever the system is in full automatic control mode In this mode the system automatically activates the pump heater to filter the water maintain the set water temperature If this light is flashing the water sensor is not detecting any water Pump Light The GREEN Pump indicator light will appear on the touchpad whenever the pump is running in both auto manual use mode Heater Light ...

Страница 4: ...ean up cycle can be initiated to filter the water after the spa pool has been used This is done by simply pushing the Pump Button to leave Auto Mode switch on the pump This will circulate the water through the filter for 90 minutes After 90 minutes the system will return to Auto Mode maintain the temperature ready for the next time the spa pool is used Adjusting Minimum Filtration Time First push ...

Страница 5: ...heat out Also make sure the spa is shaded from direct sunlight Do not operate your water heater in ambient temperatures over 40 C WARNING Before using ensure that the spa pool has been connected to a suitable weather protected outlet socket equipped with a double pole isolating switch which is of the correct rating and complies with the local wiring regulations When installing refer to your local ...

Страница 6: ...r has been held down for more than one minute This may be caused by the pool cover pressing on the touchpad or by water getting into the touchpad or by damage to the touchpad or its cable Try to reset the spa If there is still a problem then contact your spa pool supplier Error 4 No Water Sensor This error indicates a problem with the optical water sensor in the heater The problem may be caused by...

Страница 7: ...ater element thermostat pockets High pH will cause scale formation cloudy water Total Alkalinity This is a measure of how resistant your spa water is to change of pH A low TA 0 80 ppm will allow the pH to fluctuate rapidly normally to the acid end will make it very hard to correct the pH back to the ideal range Chlorine Levels of sanitiser are important to prevent the build up of bacteria algae in...

Страница 8: ...sed by Davey on the basis of their product knowledge and reasonable judgement and will be accepted if a relevant defect is found the warranty claim is made during the relevant warranty period and none of the excluded conditions listed above apply The customer will be notified of the warranty decision in writing and if found to be invalid the customer must organise collection of the product at thei...