background image

6

4.3 DynaDrive with self-priming and air handling capacity

Your DynaDrive has the benefit of a new upgraded self-priming and air handling capability. While Davey must 

stress the overall requirement for all suction lines to be airtight, we also are aware that sometimes removing 

air from suction lines or stopping minor leaks can be difficult. For this reason, Davey have incorporated 

special features into your new pump or pressure system to make operation easier and more dependable.
To help you get the most from this new capability please read this addendum in conjunction with the full 

Installation and Operating Manual included with your pump.
Plumbing: Pay special attention to ensuring the suction pipe and associated fittings are airtight. The absence 

of a water leak on the suction line may not confirm that the pipe or fittings are airtight.
Should the suction line contain air pockets it can aid the priming process greatly if you can temporarily isolate 

the discharge line from the pump and instead use an adjacent tap to allow the pump to discharge water until full 

prime is established. Such a facility is also useful for future servicing and troubleshooting should it be required.
Priming: Filling the pump and suction line with water is made much easier by filling from the outlet side and 

allowing any trapped air in the pump to evacuate via one of the plugged holes on the pump casing. 

•  Remove the tee piece on the top of the pump when trying to fill as this contains a check (one-way) valve, 

that won’t otherwise allow water to enter the pump casing;

•  Remove priming plug and fill casing and suction line (on flooded suction, simply open gate valve to 

pump). When full, replace priming plug; 

•  Ensure outlet nearest to pump is open;

•  Ensure all valves in suction line are open;

•  Switch on power. All LEDs on the display will flash; 

•  Refer section “6.1 Start Up Procedure”. A full flow of water should be discharged from the open tap.

4.4 Power connection

IMPORTANT: Long extension leads should be avoided as they often have insufficient 

current carrying capacity to run electric motors, hence they can cause substantial 

voltage drop and operating problems.

If the electrical fittings in your country make it necessary to remove the plug from the lead fixed to the motor 

care should be taken to ensure that the earth conductor green/yellow in the lead is properly connected to a 

good earth.

ATTENTION: Ensure that any and all electrical work is only undertaken by an 

authorized electrician.

The electrical connections and checks must be made by a qualified electrician and comply with applicable 

local standards. Poor installation, or poor power supply may even result in electrical fires!

ATTENTION: Automatic reset thermal overloads will allow the pump to restart without 

warning. ALWAYS disconnect the pump motor from the electrical supply before 

maintenance or repairs.

NOTE: 

•  Ensure motor is connected to power supply specified on nameplate;
•  Although the Davey electric motor is specifically engineered to perform on a range of power supply 

voltages, malfunctions or failure caused by adverse voltage supply conditions are not covered under 

guarantee.

ATTENTION: We are obliged to inform you that this pump is not to be used by children, 

or infirm persons and must not be used as a toy by children. Some insects such as 

small ants, find electrical devices attractive for various reasons. If your pump enclosure 

is susceptible to insect infestation you should implement a suitable pest control plan.

Содержание DynaDrive DD160-19

Страница 1: ...Instructions ATTENTION Please refer to www bit ly dynadrive for any product information updates or simply scan this QR code These can also be found on the product nameplate Please pass these instruct...

Страница 2: ...riming and air handling capacity 6 4 4 Power connection 6 4 5 The pressure tank 7 5 FEATURES 8 5 1 System features 8 5 2 DynaDrive display layout 8 5 3 VSD features 9 6 OPERATION 9 6 1 Start up proced...

Страница 3: ...ironment The pump enclosure has adequate drainage in the event of leakage Any transport plugs are removed The pipework is correctly sealed and supported The pump is primed correctly The power supply i...

Страница 4: ...ar point installations When a pump is installed on a spear or well point a check valve fitted immediately on top of the spear point itself see figure 3 3 Do not install the check valve at the pump or...

Страница 5: ...sible to adjust the pressure set point Some plumbing authorities impose a pressure limitation on the pressure of water into a dwelling Consideration of operating pressures should also be given to appl...

Страница 6: ...open gate valve to pump When full replace priming plug Ensure outlet nearest to pump is open Ensure all valves in suction line are open Switch on power All LEDs on the display will flash Refer sectio...

Страница 7: ...ng to isolate the pressure tank and release the water pressure from the tank beforehand or Release all water pressure from the pressure tank by switching off the pump at the power point and opening th...

Страница 8: ...ates reducing the inconvenience of pressure variation in showers etc Allows for independent switch to override DynaDrive operation This could be particularly handy if using a float switch in a source...

Страница 9: ...n from onsite brown outs by way of shut down visual alarm auto re try after correct voltage regained Protection from motor locked rotor by way of auto shut down Adaptable for daisy chain multiple pump...

Страница 10: ...ve controller measures warm or humid weather It is possible for the DynaDrive controller fan to be running even if the DynaDrive pump isn t Figure 6 2 P N 16115 1 B Pset 400 Pact 0 To start the DynaDr...

Страница 11: ...ndby maintaining pressure see figure 6 4 Figure 6 4 P N 16115 1 B Pset 400 Pact 400 6 2 Manual override In addition to automated control DynaDrive can also be run in manual override on should the need...

Страница 12: ...and hold the Prime button The pump will turn on and continue to run until the Prime button is released see figure 6 6 While the pump is in manual override the Prime LED will illuminate orange see fig...

Страница 13: ...continue to show the pressure set but changes from showing actual pressure to the frequency of power supplying the motor see figure 6 7 This dictates the speed that the motor runs Figure 6 7 P N 16115...

Страница 14: ...nstallation chapter The set pressure cannot be changed while the pump is running or in automatic mode To change the set pressure Ensure automated control is turned off To turn the automated control of...

Страница 15: ...back to normal display To change the set pressure use the Menu up button or Menu down button Pressure changes are in multiples of 10kPa Once you ve reached your new set point see figure 6 11 Figure 6...

Страница 16: ...ust up the min frequency setting refer section 7 4 and install a larger pressure tank If you have any further concerns please contact your local Davey representative 6 6 Decommissioning the DynaDrive...

Страница 17: ...override DynaDrive operation DynaDrive has the ability to be overridden by a separate switch This may be of benefit if using a float switch on a source tank eg rainwater tank To wire in an independen...

Страница 18: ...ve will pause Davey recommends a float switch cable no longer than 3m when using 2 x 0 25mm2 cable If the switch overrides DynaDrive to pause the DynaDrive display will show a flashing Fault LED The A...

Страница 19: ...remote switch Ensure automated control is turned off To turn the automated control off push the Automatic on manual off button The green Automatic LED will turn off see figure 7 4 Figure 7 4 P N 1611...

Страница 20: ...hain multiple DynaDrive systems It is possible to run two DynaDrive pumps in parallel with a shared discharge line This can be particularly useful in applications where the system s maximum flow rate...

Страница 21: ...uggests limiting the distance between the pumps to 2m To set up multiple DynaDrive to run in a common manifolded system use the following The primary pump is indicated by a solid green Automatic LED e...

Страница 22: ...ve controller delegated as the MASTER 7 4 Changing the min frequency The default minimum frequency of DynaDrive is 15Hz This can be changed by Ensure automated control is turned off To turn the automa...

Страница 23: ...hrough to Min Freq Use the Menu up button and Menu down button to change the setting to The setting will change by 5Hz Press the Enter button to save settings and return to the HOME SCREEN Now restart...

Страница 24: ...the menu will revert back to normal display Using the Menu up button and Menu down button scroll through to Cut in Use the Menu up button and Menu down button to change the setting to adjust the cut i...

Страница 25: ...DD60 10 DD90 11 DD90 13 DD160 19 Inlet BSP F 1 1 Discharge outlet BSP M 1 Pressure tank outlet top BSP F 1 Default nominal operating press kPa 400 Number of stages impellers 6 5 6 5 Maximum pump press...

Страница 26: ...Frequency incoming power Hz 50 60Hz Input power P1 kW 1 1 1 3 1 6 2 1 Output power P2 kW 0 8 0 9 1 1 1 5 Running current A 7 4 8 6 12 8 Insulation class F IP rating 55 8 5 Materials of construction P...

Страница 27: ...not dismantle spring under pressure IMPORTANT Do not use hydrocarbon based or hydrocarbon propelled sprays around the electrical components of this pump During servicing use only approved non petroch...

Страница 28: ...n HM60 10T Figure 11 1 16 19 18 14 11 10 9 8 8 8 6 5 7 7 7 12 15 13 20 21 22 23 24 25 4 3 2 1 ITEM NOTES DESCRIPTION QTY REQ D PART NO 1 Casing Front DD60 10 DD90 11 DD90 13 1 13656 6SP 1 Casing Front...

Страница 29: ...D60 DD90 series 1 13663 11 Stage body Final DD160 series 1 13675 12 Spacer Destage 60 10 DD90 11 1 13696 1 13 B Washer Cup Not applicable to DD160 models As required 13666 13 Washer Cup DD160 2 13693...

Страница 30: ...30 NOTES...

Страница 31: ...31...

Страница 32: ...he right to replace defective parts of the product with parts or components of similar quality grade and composition where an identical part or component is not available Goods presented for repair ma...

Отзывы: