3.5 Installs with a mains pressure hot water system

ATTENTION: Always ensure hot water systems are installed in compliance with 

manufacturers recommendations and in accordance with all local regulations.

To protect your system from damage caused by back pressure from hot 

water systems, see figure 3.5. 

You should always have installed on the hot water inlet an approved non-

return valve.

Davey Water Products Pty Ltd cannot accept responsibility for loss or 

damage resulting from incorrect, or unauthorised installations.

4. INSTALLATION

4.1 Choosing a site

Choose a clean and dry site with a firm base as close to the water source as possible with correct power 

supply. Make sure your pump is always connected to an adequate, reliable source of clean water. To protect 

your pump from the weather, make sure the pump house is both waterproof, frost free and has adequate 

ventilation. The pump should be mounted on a firm base allowing for drainage, to avoid damage to flooring etc., 

that over time may occur from leaking pipe joints or pump seals. Do not mount the pump vertically. Never place 

flammable materials on, or near your pump.
The DynaDrive controller comes pre-set to maintain a pressure of 400kPa. However, it is possible to adjust 

the pressure set point. Some plumbing authorities impose a pressure limitation on the pressure of water into a 

dwelling. Consideration of operating pressures should also be given to appliances within the dwelling. If unsure, 

check with local authorities, or a licenced contractor.

4.2 Pipe connections

IMPORTANT: Suction leaks are the largest cause of poor pump performance and are 

difficult to detect. Ensure all connections are completely sealed using thread tape only. 

DO NOT USE SEALING COMPOUNDS, HEMP, OR PIPE DOPE.

For best performance use P.V.C, or polythene pipe 

with a diameter at least the same as the pump’s 

inlet. Larger diameter pipe may be used to minimise 

resistance to flow when pumping for distances longer 

than 5m (16’). Use unions at pipe connections to 

enable easy removal and servicing. 
Use enough “plumbers’ tape” to ensure airtight seal 

and hand tighten only, do not screw connections all 

the way into suction port, see figure 4.1. To prevent 

strain on pump thread always support heavy inlet and 

outlet pipes. 
Lay suction pipe at a constant gradient to avoid air pockets which may reduce pump efficiency, see figure 4.2.

Avoid installing 90° elbows before the suction inlet of the pump, within a 

distance equivalent to 5 x pipe diameter. For example: if using 40mm suction 

pipe, avoid installing a 90° elbow within 200mm of the pump inlet. This will 

assist laminar flow.

Figure 3.5

Figure 4.1

Figure 4.2

Содержание DynaDrive DD160-19

Страница 1: ...Instructions ATTENTION Please refer to www bit ly dynadrive for any product information updates or simply scan this QR code These can also be found on the product nameplate Please pass these instruct...

Страница 2: ...riming and air handling capacity 6 4 4 Power connection 6 4 5 The pressure tank 7 5 FEATURES 8 5 1 System features 8 5 2 DynaDrive display layout 8 5 3 VSD features 9 6 OPERATION 9 6 1 Start up proced...

Страница 3: ...ironment The pump enclosure has adequate drainage in the event of leakage Any transport plugs are removed The pipework is correctly sealed and supported The pump is primed correctly The power supply i...

Страница 4: ...ar point installations When a pump is installed on a spear or well point a check valve fitted immediately on top of the spear point itself see figure 3 3 Do not install the check valve at the pump or...

Страница 5: ...sible to adjust the pressure set point Some plumbing authorities impose a pressure limitation on the pressure of water into a dwelling Consideration of operating pressures should also be given to appl...

Страница 6: ...open gate valve to pump When full replace priming plug Ensure outlet nearest to pump is open Ensure all valves in suction line are open Switch on power All LEDs on the display will flash Refer sectio...

Страница 7: ...ng to isolate the pressure tank and release the water pressure from the tank beforehand or Release all water pressure from the pressure tank by switching off the pump at the power point and opening th...

Страница 8: ...ates reducing the inconvenience of pressure variation in showers etc Allows for independent switch to override DynaDrive operation This could be particularly handy if using a float switch in a source...

Страница 9: ...n from onsite brown outs by way of shut down visual alarm auto re try after correct voltage regained Protection from motor locked rotor by way of auto shut down Adaptable for daisy chain multiple pump...

Страница 10: ...ve controller measures warm or humid weather It is possible for the DynaDrive controller fan to be running even if the DynaDrive pump isn t Figure 6 2 P N 16115 1 B Pset 400 Pact 0 To start the DynaDr...

Страница 11: ...ndby maintaining pressure see figure 6 4 Figure 6 4 P N 16115 1 B Pset 400 Pact 400 6 2 Manual override In addition to automated control DynaDrive can also be run in manual override on should the need...

Страница 12: ...and hold the Prime button The pump will turn on and continue to run until the Prime button is released see figure 6 6 While the pump is in manual override the Prime LED will illuminate orange see fig...

Страница 13: ...continue to show the pressure set but changes from showing actual pressure to the frequency of power supplying the motor see figure 6 7 This dictates the speed that the motor runs Figure 6 7 P N 16115...

Страница 14: ...nstallation chapter The set pressure cannot be changed while the pump is running or in automatic mode To change the set pressure Ensure automated control is turned off To turn the automated control of...

Страница 15: ...back to normal display To change the set pressure use the Menu up button or Menu down button Pressure changes are in multiples of 10kPa Once you ve reached your new set point see figure 6 11 Figure 6...

Страница 16: ...ust up the min frequency setting refer section 7 4 and install a larger pressure tank If you have any further concerns please contact your local Davey representative 6 6 Decommissioning the DynaDrive...

Страница 17: ...override DynaDrive operation DynaDrive has the ability to be overridden by a separate switch This may be of benefit if using a float switch on a source tank eg rainwater tank To wire in an independen...

Страница 18: ...ve will pause Davey recommends a float switch cable no longer than 3m when using 2 x 0 25mm2 cable If the switch overrides DynaDrive to pause the DynaDrive display will show a flashing Fault LED The A...

Страница 19: ...remote switch Ensure automated control is turned off To turn the automated control off push the Automatic on manual off button The green Automatic LED will turn off see figure 7 4 Figure 7 4 P N 1611...

Страница 20: ...hain multiple DynaDrive systems It is possible to run two DynaDrive pumps in parallel with a shared discharge line This can be particularly useful in applications where the system s maximum flow rate...

Страница 21: ...uggests limiting the distance between the pumps to 2m To set up multiple DynaDrive to run in a common manifolded system use the following The primary pump is indicated by a solid green Automatic LED e...

Страница 22: ...ve controller delegated as the MASTER 7 4 Changing the min frequency The default minimum frequency of DynaDrive is 15Hz This can be changed by Ensure automated control is turned off To turn the automa...

Страница 23: ...hrough to Min Freq Use the Menu up button and Menu down button to change the setting to The setting will change by 5Hz Press the Enter button to save settings and return to the HOME SCREEN Now restart...

Страница 24: ...the menu will revert back to normal display Using the Menu up button and Menu down button scroll through to Cut in Use the Menu up button and Menu down button to change the setting to adjust the cut i...

Страница 25: ...DD60 10 DD90 11 DD90 13 DD160 19 Inlet BSP F 1 1 Discharge outlet BSP M 1 Pressure tank outlet top BSP F 1 Default nominal operating press kPa 400 Number of stages impellers 6 5 6 5 Maximum pump press...

Страница 26: ...Frequency incoming power Hz 50 60Hz Input power P1 kW 1 1 1 3 1 6 2 1 Output power P2 kW 0 8 0 9 1 1 1 5 Running current A 7 4 8 6 12 8 Insulation class F IP rating 55 8 5 Materials of construction P...

Страница 27: ...not dismantle spring under pressure IMPORTANT Do not use hydrocarbon based or hydrocarbon propelled sprays around the electrical components of this pump During servicing use only approved non petroch...

Страница 28: ...n HM60 10T Figure 11 1 16 19 18 14 11 10 9 8 8 8 6 5 7 7 7 12 15 13 20 21 22 23 24 25 4 3 2 1 ITEM NOTES DESCRIPTION QTY REQ D PART NO 1 Casing Front DD60 10 DD90 11 DD90 13 1 13656 6SP 1 Casing Front...

Страница 29: ...D60 DD90 series 1 13663 11 Stage body Final DD160 series 1 13675 12 Spacer Destage 60 10 DD90 11 1 13696 1 13 B Washer Cup Not applicable to DD160 models As required 13666 13 Washer Cup DD160 2 13693...

Страница 30: ...30 NOTES...

Страница 31: ...31...

Страница 32: ...he right to replace defective parts of the product with parts or components of similar quality grade and composition where an identical part or component is not available Goods presented for repair ma...

Отзывы: