24
Figure 7.10
P/
N
:1
611
5-
1 B
Pset 400
Pact 400
• Once the motor has slowed to a stop, press and hold the
Menu button
for ~ 5 seconds. The display
will change to show your current set pressure, see figure 7.11;
Figure 7.11
P/
N
:1
611
5-
1 B
pressure
400 kPa
• If the controls are untouched for ~ 30 seconds, the menu will revert back to normal display;
• Using the
Menu up button
and
Menu down button
scroll through to Cut-in;
• Use the
Menu up button
and
Menu down button
to change the setting to adjust the cut-in
variance by 10kPa;
• Press the
Enter button
to save settings and return to the
HOME SCREEN
;
• Now restart automatic operation by pressing
Automatic on / manual off button
.
In a daisy-chain installation, the cut-in of the secondary pump occurs after the same pressure drop as the
primary pump is set.