23
• Once the motor has slowed to a stop, press and hold the
Menu button
and
Enter button
for ~
5 seconds. The display will change to show your current set pressure, see figure 7.9;
Figure 7.9
P/
N
:1
611
5-
1 B
pressure
400 kPa
• If the controls are untouched for ~ 30 seconds, the menu will revert back to normal display;
• Using the
Menu up button
and
Menu down button
scroll through to Min Freq.
• Use the
Menu up button
and
Menu down button
to change the setting to. The setting will
change by 5Hz;
• Press the
Enter button
to save settings and return to the HOME SCREEN;
• Now restart automatic operation by pressing
Automatic on / manual off button
.
7.5 Changing cut-in pressure point
The default cut-in pressure of DynaDrive is 50kPa less than set point. This can be changed by:
• Ensure
automated control
is turned off. To turn the automated control off, push the
Automatic on /
manual off button
.
• The green
Automatic LED
will turn off, see figure 7.10;