CASCADE SYSTEM
84
SH4 BASE-STANDARD
CONNECTION
In order to connect SH4 units in a cascade system, follow the steps below:
1. Connect the M12-5 poles
female
connector of the MASTER unit to the M12-5
poles
male
connector of following slave unit.
2. Same way a LAST SLAVE can be connected to the MID SLAVE.
RX connection
NOTE: When the distance between units doesn't allow a direct connection
an optional M12 male to M12 female 5 pole cable may be used up to 10 m
cable length. Refer to Accessories appendix to see the available models.
NOTE: When using a SH4-XX-XXXX-C-5-5 model as LAST SLAVE the M12
female connector will provide muting inputs with same pinout of MASTER
unit (depending on the configuration for advanced models). For more
details please refer to SH4-XX-XXXX-SM-8-5 or SH4-XX-XXXX-A-12-5
connections on the respective Product Reference Guide.
NOTE: When using an SH4-XX-XXXX-A-12-5 model as MASTER unit, pin 11
(GP_IO2) from 12 poles male connector must be left floating.
NOTE: See chapter “Connections” for consult the connector’s pin-out.
M12 8 or 12 pin, male
M12 5 pin
female
M12 5 pin
male
M12 5 pin
female
M12 5 pin
male
M12 5 pin female or none
Содержание SH4 BASE-STANDARD
Страница 1: ...SH4 BASE STANDARD PRODUCT REFERENCE GUIDE Safety Light Curtains...
Страница 6: ...CONTENTS vi SH4 BASE STANDARD...
Страница 13: ...COMPLIANCE PRODUCT REFERENCE GUIDE 5...
Страница 29: ...GENERAL INFORMATION ON DEVICE POSITIONING PRODUCT REFERENCE GUIDE 21...
Страница 33: ...PRODUCT REFERENCE GUIDE 25...
Страница 38: ...ELECTRICAL CONNECTIONS 30 SH4 BASE STANDARD...
Страница 59: ...SH4 X XXXX X X MODELS PRODUCT REFERENCE GUIDE 51...
Страница 65: ...PRODUCT REFERENCE GUIDE 57...
Страница 69: ...RESPONSE TIMES PRODUCT REFERENCE GUIDE 61...
Страница 73: ...SH4 2 3 4 XXXX X X PRODUCT REFERENCE GUIDE 65...
Страница 75: ...METAL ANGLED FIXING BRACKET PRODUCT REFERENCE GUIDE 67...
Страница 99: ...RECOVERY TIME PRODUCT REFERENCE GUIDE 91...