TEST
PRODUCT REFERENCE GUIDE
41
TEST
The TEST function can be activated by keeping TEST signal HIGH (
pin 2 on TX unit
) for at
least 0.5 seconds as shown in the following timing diagram.
The TEST disables the emission stage, so the RX side sees interrupted beams (all) and
the OSSD goes low within response time. As is shown in the timing diagram below, the
OSSDs go OFF (BREAK status) after 0.5s (plus a cycle time) and after the response time
of the light curtain.
Figure 10: OSSDs timing for test on TX
NOTE: On Body models only, TEST input may be used to set Emission
Range. Refer to the next paragraph for more information.
CAUTION: At runtime keep TEST input connected to 24Vdc for more than 2s
and less than 5s to change range setting from Long to Short or vice versa.
Emission Range setting is kept also after a power cycle. Refer to the next
paragraph for more information.
TEST
24Vdc
EMISSION STATUS
OSSDs STATUS
0.5s
0V/FLOAT
OFF
ON
SAFE
BREAK
RESPONSE TIME
RECOVERY TIME
2s
Содержание SH4 BASE-STANDARD
Страница 1: ...SH4 BASE STANDARD PRODUCT REFERENCE GUIDE Safety Light Curtains...
Страница 6: ...CONTENTS vi SH4 BASE STANDARD...
Страница 13: ...COMPLIANCE PRODUCT REFERENCE GUIDE 5...
Страница 29: ...GENERAL INFORMATION ON DEVICE POSITIONING PRODUCT REFERENCE GUIDE 21...
Страница 33: ...PRODUCT REFERENCE GUIDE 25...
Страница 38: ...ELECTRICAL CONNECTIONS 30 SH4 BASE STANDARD...
Страница 59: ...SH4 X XXXX X X MODELS PRODUCT REFERENCE GUIDE 51...
Страница 65: ...PRODUCT REFERENCE GUIDE 57...
Страница 69: ...RESPONSE TIMES PRODUCT REFERENCE GUIDE 61...
Страница 73: ...SH4 2 3 4 XXXX X X PRODUCT REFERENCE GUIDE 65...
Страница 75: ...METAL ANGLED FIXING BRACKET PRODUCT REFERENCE GUIDE 67...
Страница 99: ...RECOVERY TIME PRODUCT REFERENCE GUIDE 91...