INSTALLATION

Master and Switched Ports

Connection to the Switched A-H ports is made using 25 pin D Subminiature connectors on the rear of
the unit. The following leads are supported for Asynchronous communications:

Pin #              Designation

   2

Transmit Data

   3

Receive Data

   4

Request to Send

   5

Clear to Send

   6

Data Set Ready

   7

Signal Ground

   8

Data Carrier Detect

  20

Data Terminal Ready

The eight switched ports A-H are wired DCE (output
data on pin 3,RD). The Master port is wired for as DTE.
To directly connect a terminal device to the Master
Port, a Null cable is required.  Refer to Figure 4 below.

RTS / DTR Selection

Jumpers JP1 through JP8 allows selection of RTS or DTR as the control lead used in the Lead Control
mode.  To access these jumpers, disconnect the power source and remove the top cover of the 8P-
CAS by loosening the two screws on the underside of the unit.  The jumpers are located as shown
below on Figure 3.

 

Figure 3

Component Location

Typical
Port A-H

RTS
Mon.

Switch
Control

Code
Mon.

Electronic
4 Way 
Switch

2  TD

3  RD

4  RTS

5  CTS
6  DSR
8  DCD

DTR

20

7  SG

2  TD

3  RD

4  RTS

5  CTS
6  DSR
8  DCD

DTR

20

7  SG

Master
Port

                  Figure 2

                   System Diagram

DTR

RTS

Содержание 8P-MAS

Страница 1: ...llows convenient naming of each port and setup of all 8P MAS parameters Lead Control This option allows any of the eight ports to access the master port by raising its Request To Send RTS or Data Term...

Страница 2: ...system sends a login prompt LOGIN Enter the Security Code The Factory Default Security Code is TEST Please change this code as soon as possible Remember your code When connecting through a modem three...

Страница 3: ...configuration menu is used to set most operational features of the 8P MAS 1 DEVICE LABELS 2 PASSWORD 3 BAUD 9600 4 PARITY DATA N 8 5 LEAD CTL N 6 MODE MODEM 7 TIMEOUT 0 X EXIT ENTER Device Labels This...

Страница 4: ...d Rate ENTER BAUD Valid selections are 300 600 1200 2400 4800 9600 19200 38400 57600 and 115200 This changes only the default speed The Auto Rate Detector can always be invoked by sending the Enter Ke...

Страница 5: ...r port by raising RTS or DTR When the selected lead goes high on any of the eight ports it will establish a connection from that port to the Master Port This works on a queued basis as subsequent port...

Страница 6: ...red for as DTE To directly connect a terminal device to the Master Port a Null cable is required Refer to Figure 4 below RTS DTR Selection Jumpers JP1 through JP8 allows selection of RTS or DTR as the...

Страница 7: ...l SPECIFICATIONS Model 8P MAS Physical 19 Wide x 6 5 Deep x 1 75 High Power Supply Input 120VAC via Wall Mounted Power Supply UL CAS approved Output 9VDC 1 Amp Communications Speed 300 to 115 200 bps...

Страница 8: ...201 967 8788 to receive a Return Materials Authorization RMA Number prior to sending any equipment back for repair Include all cables power supplies and proof of purchase with shipment THIS WARRANTY D...

Отзывы: