Model 8P-MAS

Page 4

CURRENT LABEL PORT A PORT A

NEW LABEL PORT A > Your New Name

PORT LABEL  CHANGED FROM: PORT A

                      TO: Your New Name

SAVE CHANGES? (Y/N) >

Password

To change the password, it must be reentered.  Then a prompt for a new password, then a confirmation
of the new password.  The password may be up to eight characters and is case sensitive.

LOGIN > TEST

ENTER NEW PASSWORD > TEST

RE-ENTER NEW PASSWORD > TEST

PASSWORD CHANGED

Please remember you password.  If you forget your password, the unit needs to be returned to
Dataprobe for re-initialization.  There is a charge for this.

Set Baud Rate

ENTER BAUD >

Valid selections are 300  600  1200  2400  4800  9600  19200  38400  57600 and 115200
This changes only the default speed.  The Auto Rate Detector can always be invoked by sending the
Enter Key several times.

Set Character Format

ENTER N,E,O >

Enter only the Parity, N, E or O  for None, Even, Odd respectively.  The 8P-MAS will automatically
adjust for the number of data bits and 1 stop bit.

Set for Lead Control

  Yes or No

ENTER Y/N  >

Enter Y to add RTS/DTR Lead control to the 8P-MAS.  This mode allows the RTS or DTR of Ports A
through H to select the Master Port.   Change this setting to Yes if you require one or more of the
devices connected to ports A through H to be able to dial out through the modem on the Master Port.
below for a detailed description of Lead control.

Содержание 8P-MAS

Страница 1: ...llows convenient naming of each port and setup of all 8P MAS parameters Lead Control This option allows any of the eight ports to access the master port by raising its Request To Send RTS or Data Term...

Страница 2: ...system sends a login prompt LOGIN Enter the Security Code The Factory Default Security Code is TEST Please change this code as soon as possible Remember your code When connecting through a modem three...

Страница 3: ...configuration menu is used to set most operational features of the 8P MAS 1 DEVICE LABELS 2 PASSWORD 3 BAUD 9600 4 PARITY DATA N 8 5 LEAD CTL N 6 MODE MODEM 7 TIMEOUT 0 X EXIT ENTER Device Labels This...

Страница 4: ...d Rate ENTER BAUD Valid selections are 300 600 1200 2400 4800 9600 19200 38400 57600 and 115200 This changes only the default speed The Auto Rate Detector can always be invoked by sending the Enter Ke...

Страница 5: ...r port by raising RTS or DTR When the selected lead goes high on any of the eight ports it will establish a connection from that port to the Master Port This works on a queued basis as subsequent port...

Страница 6: ...red for as DTE To directly connect a terminal device to the Master Port a Null cable is required Refer to Figure 4 below RTS DTR Selection Jumpers JP1 through JP8 allows selection of RTS or DTR as the...

Страница 7: ...l SPECIFICATIONS Model 8P MAS Physical 19 Wide x 6 5 Deep x 1 75 High Power Supply Input 120VAC via Wall Mounted Power Supply UL CAS approved Output 9VDC 1 Amp Communications Speed 300 to 115 200 bps...

Страница 8: ...201 967 8788 to receive a Return Materials Authorization RMA Number prior to sending any equipment back for repair Include all cables power supplies and proof of purchase with shipment THIS WARRANTY D...

Отзывы: