OPERATION

The 8P-MAS is controlled principally through an ASCII terminal interface.  Access to this configuration
menu can be achieved either by: connecting via modem connected to the Master Port, or directly via
terminal (using a null cable) into the Master Port of the 8P-MAS.  See page 6 for installation details.

 

The default parameters are:    9600 bps 8 data 1 stop no parity

.

All of these parameters can be changed through the programming menu.

Auto Rate Detect:

   The 8P-MAS automatically determines the speed of the connection.  If the Login

Prompt does not appear, press the Enter Key  several times to enable the Auto Rate Detect.

Once connected to the 8P-MAS, the system sends a login prompt.

LOGIN >

Enter the Security Code.  

The Factory Default Security Code is:   TEST

.  Please change this code as

soon as possible.  Remember your code.  When connecting through a modem, three incorrect attempts
to enter the security code will cause the 8P-MAS to terminate the call.  When the correct code is
entered, the Main Menu appears:

A)  PORT A

B)  PORT B

C)  PORT C

D)  PORT D

E)  PORT E

F)  PORT F

G)  PORT G

H)  PORT H

1) LOCAL CONFIGURATION

X) EXIT

ENTER PORT >

This allows selection of any port, Local Configuration to access the programming menu or terminate the
current session.   When Exit is selected, the 8P-MAS logs the user out and a new Login is required.

To select a port, enter the letter desired, followed by the Enter Key.  Once a port is selected, the
8P-MAS will clear the screen and generate the following message:

PORT A SELECTED

ENTER ESC{PASSWORD}ESC TO RETURN TO MENU

Содержание 8P-MAS

Страница 1: ...llows convenient naming of each port and setup of all 8P MAS parameters Lead Control This option allows any of the eight ports to access the master port by raising its Request To Send RTS or Data Term...

Страница 2: ...system sends a login prompt LOGIN Enter the Security Code The Factory Default Security Code is TEST Please change this code as soon as possible Remember your code When connecting through a modem three...

Страница 3: ...configuration menu is used to set most operational features of the 8P MAS 1 DEVICE LABELS 2 PASSWORD 3 BAUD 9600 4 PARITY DATA N 8 5 LEAD CTL N 6 MODE MODEM 7 TIMEOUT 0 X EXIT ENTER Device Labels This...

Страница 4: ...d Rate ENTER BAUD Valid selections are 300 600 1200 2400 4800 9600 19200 38400 57600 and 115200 This changes only the default speed The Auto Rate Detector can always be invoked by sending the Enter Ke...

Страница 5: ...r port by raising RTS or DTR When the selected lead goes high on any of the eight ports it will establish a connection from that port to the Master Port This works on a queued basis as subsequent port...

Страница 6: ...red for as DTE To directly connect a terminal device to the Master Port a Null cable is required Refer to Figure 4 below RTS DTR Selection Jumpers JP1 through JP8 allows selection of RTS or DTR as the...

Страница 7: ...l SPECIFICATIONS Model 8P MAS Physical 19 Wide x 6 5 Deep x 1 75 High Power Supply Input 120VAC via Wall Mounted Power Supply UL CAS approved Output 9VDC 1 Amp Communications Speed 300 to 115 200 bps...

Страница 8: ...201 967 8788 to receive a Return Materials Authorization RMA Number prior to sending any equipment back for repair Include all cables power supplies and proof of purchase with shipment THIS WARRANTY D...

Отзывы: