background image

Model 8P-MAS

Page 7

2
3
4
5
6
7
8
20

Null Connection to 

Control Leads Required vary from 
device to device.  Consult your 
operations manual for details on 
your specific needs.

2
3
4
5
6
7
8
20

Figure 4
Null Modem Connection
 to terminal

SPECIFICATIONS

Model 8P-MAS

Physical

19” Wide x 6.5” Deep x 1.75” High.

Power Supply

Input :   120VAC  via Wall Mounted Power Supply.  UL/CAS approved.
Output: +9VDC @ 1 Amp

Communications

Speed:

300 to 115,200 bps.

Character Format:  

8 data, no parity, 1 stop bit / 7 data even or odd parity, 1 stop bit.

Interface:  

RS-232 Asynchronous .

Connectors:  

Ports A through H;   25 pin D Subminiature. Female.

Master Port:  

25 pin D Subminiature, Male.

Pins Supported:  

2-8, 20.

Содержание 8P-MAS

Страница 1: ...llows convenient naming of each port and setup of all 8P MAS parameters Lead Control This option allows any of the eight ports to access the master port by raising its Request To Send RTS or Data Term...

Страница 2: ...system sends a login prompt LOGIN Enter the Security Code The Factory Default Security Code is TEST Please change this code as soon as possible Remember your code When connecting through a modem three...

Страница 3: ...configuration menu is used to set most operational features of the 8P MAS 1 DEVICE LABELS 2 PASSWORD 3 BAUD 9600 4 PARITY DATA N 8 5 LEAD CTL N 6 MODE MODEM 7 TIMEOUT 0 X EXIT ENTER Device Labels This...

Страница 4: ...d Rate ENTER BAUD Valid selections are 300 600 1200 2400 4800 9600 19200 38400 57600 and 115200 This changes only the default speed The Auto Rate Detector can always be invoked by sending the Enter Ke...

Страница 5: ...r port by raising RTS or DTR When the selected lead goes high on any of the eight ports it will establish a connection from that port to the Master Port This works on a queued basis as subsequent port...

Страница 6: ...red for as DTE To directly connect a terminal device to the Master Port a Null cable is required Refer to Figure 4 below RTS DTR Selection Jumpers JP1 through JP8 allows selection of RTS or DTR as the...

Страница 7: ...l SPECIFICATIONS Model 8P MAS Physical 19 Wide x 6 5 Deep x 1 75 High Power Supply Input 120VAC via Wall Mounted Power Supply UL CAS approved Output 9VDC 1 Amp Communications Speed 300 to 115 200 bps...

Страница 8: ...201 967 8788 to receive a Return Materials Authorization RMA Number prior to sending any equipment back for repair Include all cables power supplies and proof of purchase with shipment THIS WARRANTY D...

Отзывы: