Model 8P-MAS

Page 3

At this point the Master Port is connected through to the port selected.  The 8P-MAS is passive to the
messages sent between the Master Port and the port selected.  To terminate the session with the
current port and bring back the menu, enter the escape character plus the security code and another
escape character.  i.e.  

E

s

C

TEST

E

s

C

Local Configuration

A configuration menu is used to set most operational features of the 8P-MAS.

1)   DEVICE LABELS

2)   PASSWORD

3)   BAUD: 9600

4)   PARITY/DATA: N,8

5)  LEAD CTL: N

6)  MODE: MODEM

7)  TIMEOUT: 0

X)  EXIT

ENTER >

Device Labels

This allows changing of the screen labels for the ports and power control outlets.

A) PORT A

B) PORT B

C)  PORT C

D)  PORT D

E)  PORT E

F)  PORT F

G)  PORT G

H)  PORT H

X)  EXIT

ENTER LABEL # (A-D) >

Enter the label to be changed.  The current label is displayed along with a prompt for the new name.
Type in a new label and then confirm the selection as shown below.  Labels can be up to 20 characters.

Содержание 8P-MAS

Страница 1: ...llows convenient naming of each port and setup of all 8P MAS parameters Lead Control This option allows any of the eight ports to access the master port by raising its Request To Send RTS or Data Term...

Страница 2: ...system sends a login prompt LOGIN Enter the Security Code The Factory Default Security Code is TEST Please change this code as soon as possible Remember your code When connecting through a modem three...

Страница 3: ...configuration menu is used to set most operational features of the 8P MAS 1 DEVICE LABELS 2 PASSWORD 3 BAUD 9600 4 PARITY DATA N 8 5 LEAD CTL N 6 MODE MODEM 7 TIMEOUT 0 X EXIT ENTER Device Labels This...

Страница 4: ...d Rate ENTER BAUD Valid selections are 300 600 1200 2400 4800 9600 19200 38400 57600 and 115200 This changes only the default speed The Auto Rate Detector can always be invoked by sending the Enter Ke...

Страница 5: ...r port by raising RTS or DTR When the selected lead goes high on any of the eight ports it will establish a connection from that port to the Master Port This works on a queued basis as subsequent port...

Страница 6: ...red for as DTE To directly connect a terminal device to the Master Port a Null cable is required Refer to Figure 4 below RTS DTR Selection Jumpers JP1 through JP8 allows selection of RTS or DTR as the...

Страница 7: ...l SPECIFICATIONS Model 8P MAS Physical 19 Wide x 6 5 Deep x 1 75 High Power Supply Input 120VAC via Wall Mounted Power Supply UL CAS approved Output 9VDC 1 Amp Communications Speed 300 to 115 200 bps...

Страница 8: ...201 967 8788 to receive a Return Materials Authorization RMA Number prior to sending any equipment back for repair Include all cables power supplies and proof of purchase with shipment THIS WARRANTY D...

Отзывы: