In ‘Calibration’ mode, the buttons allow the printer to adjust to the media being used. Calibration can be
performed either automatically or manually, as detailed below.
Before calibrating, ensure that the Printhead Carrier Assembly is latched down, that the cover is
closed, and that the media sensor has been set for the appropriate media type.
Printer and cutter faults are disabled during the Calibration mode, but can still occur while printing
“test” labels.
If at any time you wish to discard your changes and revert back to the previous calibration simply
turn off power to the printer.
To perform Calibration:
F1
Auto Media Calibration
(See Section B.4.1)
(See Section B.4.2)
Calibration Mode
F3
Analyze media
F3
F2
Analyze media backing material or reflective mark
Analyze no media condition
F1
Feeds one label for “test”
F2
Press and hold until the
Paused Light turns on
Press and
Release
F2
F3
Prints the ‘Test Label’ for “test”
F1
F3
+
Saves the current values
and resumes
Normal Mode
F1
F3
+
Accepts the current
analysis for “test”
Media Sensor Calibration
(
)
(
)
(Press and hold during power-up until the Paused Light turns off)
(The Fault Indicator flashes during analysis)