
PG4UW
79
Find & Replace dialog box
Enter the search string in the
Text to find
string input box and enter the replacement string in
the
Replace with
input box.
In
Options
box you can select prompt on replace: if program finds instance you will be asked
before program change it.
Origin
specifies where the search should start.
Direction
box specifies which way you want to search, starting from the current cursor position
(In edit mode).
Forward
(from the current position or start of buffer to the end of the buffer) is
the default.
Backward
searches toward the beginning. In view mode searches all buffer.
Press
<Esc>
or click
Cancel
button to close dialog window.
By pressing
Replace
button the dialog box is closed and a Question window is displayed. This
window contains following choices:
Yes
replaces found item and finds next
No
finds next item without replacing current one
Replace All
replaces all found items
Abort search
aborts this command
View/Edit buffer for PLD
Ctrl+F2
erase buffer with specified blank value
Ctrl+Shift+F2
fill buffer with random data
F9
go to address...
F10
change mode view / edit
F11
switch the mode of buffer data view between 1 bit and 8 bit view. It
can be also doing by mouse clicking on the button to the right of
View/Edit mode buffer indicator. This button indicates actual data
view mode (1 bit or 8 bit), too.
Arrow keys
move cursor up, down, right and left
Home/End
jump on start / end current line
PgUp/PgDn
jump on previous / next page
Ctrl+PgUp/PgDn
jump on start / end current page
Ctrl+Home/End
jump on start / end edit area
Backspace
move cursor one position left (back)
Note:
Characters 0 and 1 immediately changes content of edit area.
Buffer / Fill block
Selecting this command causes filling selected block of buffer by requested hex (or ASCII)
string.
Selecting option "Allow address history logging" activates saving of recently confirmed values.
These are saved for each device separately; count is limited to last 15 items.
Note:
Address history values are common for all buffer data manipulation dialogs.
Default address range is set according to buffer range of selected device.
Selecting option "Maintain last inserted values" causes that for the next time you open this
dialog, previously confirmed values will be reloaded as default.
Содержание 448PRO2
Страница 7: ...Introduction 7 Introduction...
Страница 12: ...12 Quick Start...
Страница 15: ...Detailed description 15 Detailed description...
Страница 16: ...16 DATAMAN 448PRO2...
Страница 30: ...30 DATAMAN 48PRO2 DATAMAN 48PRO2C...
Страница 46: ...46 DATAMAN 40PRO...
Страница 55: ...Setup 55 Setup...
Страница 60: ...60 Step 8 Installation process will start Step 9 Click Finish button to finish setup...
Страница 64: ...64 Click on Continue Anyway button For Windows Vista Click Install this driver software anyway...
Страница 66: ...66 PG4UW...
Страница 133: ...PG4UWMC 133 PG4UWMC...
Страница 146: ...146 Installation procedure customized...
Страница 151: ...Common notes 151 Common notes...
Страница 165: ...Troubleshooting and warranty 165 Troubleshooting and warranty...