
DATAMAN-48PRO2 / DATAMAN-48PRO2C
39
Selftest of programmer
Insert
48 pins diagnostic pod - type I
into ZIF socket of the programmer.
48 pins
diagnostic pod - type I
must be inserted as 48 pins device.
Run selftest of programmer in PG4UW (menu Programmer / Selftest).
Selftest of ISP connector
Insert
Diagnostic pod for ISP connectors #2
into ZIF socket of the programmer.
Diagnostic pod for ISP connectors #2
must be inserted as 48 pins device.
Interconnect 20 pins connector of
Diagnostic pod for ISP connectors #2
with an ISP
connector of the programmer with an ISP cable, included in delivery programmer package.
Be sure that pins are interconnected properly (i.e. 1-1, 2-2 ... 20-20).
Run selftest of ISP connector in PG4UW (menu Programmer / Selftest ISP connector…).
Содержание 448PRO2
Страница 7: ...Introduction 7 Introduction...
Страница 12: ...12 Quick Start...
Страница 15: ...Detailed description 15 Detailed description...
Страница 16: ...16 DATAMAN 448PRO2...
Страница 30: ...30 DATAMAN 48PRO2 DATAMAN 48PRO2C...
Страница 46: ...46 DATAMAN 40PRO...
Страница 55: ...Setup 55 Setup...
Страница 60: ...60 Step 8 Installation process will start Step 9 Click Finish button to finish setup...
Страница 64: ...64 Click on Continue Anyway button For Windows Vista Click Install this driver software anyway...
Страница 66: ...66 PG4UW...
Страница 133: ...PG4UWMC 133 PG4UWMC...
Страница 146: ...146 Installation procedure customized...
Страница 151: ...Common notes 151 Common notes...
Страница 165: ...Troubleshooting and warranty 165 Troubleshooting and warranty...