Common notes
159
1. loads data file c:\15001-25001\file_10.bin
2. saves the currently selected device settings and buffer data to project file
c:\projects\project_10.eprj
If the result of operations performed is OK, PG4UWcmd application will return ExitCode (or
ErrorLevel) value 0.
If there are some errors (can not load file or save to project file), PG4UWcmd application will
return ExitCode value equal or greater than 1.
Note:
When using the above commands, user must be sure the PG4UW is not performing any
device operation, for example device programming. If the PG4UW is busy, it will refuse the
commands and returns error status (ExitCode equal or greater than value 1).
Hardware
Due a large variety of parallel port types, a case may occur when the programmer cannot "get
concerted" with the PC. This problem may be shown as none communication between the PC
and the programmer, or by unreliable communication. If this behavior occurs, try to connect
your programmer to some other PCs or other parallel ports near you.
If you find none solution, please document the situation, i.e., provide us an accurate
description of your PC configuration, including some other circumstances bearing on the
problem in question, and advise the manufacturer of your problem. Don’t forget please enter of
PC type, manufacturer, speed, operation system, resident programs; your parallel port I/O
manufacturer and type. Use please
Device problem report
form for this purpose.
Warning:
Class A ITE notice
Devices described at this manual are class A products. In domestic
environment this products may cause radio interference in which case the
user may be required to take adequate measures.
Because
DATAMAN-448PRO2,
DATAMAN-48PRO2 and
DATAMAN-48PRO2C have internal power supply, follow these special precautions:
Circuit breakers (overcurrent protection) must be a part of building electrical installation.
Pull out power cord plug from outlet to disconnect programmer from mains. The outlet must
be placed near to programmer and must be easy accessible.
ISP (In-System Programming)
Definition
In-system programming
allows programming and reprogramming of device positioned inside
the end system. Using a simple interface, the ISP programmer communicates serially with the
device, reprogramming nonvolatile memories on the chip. In-system programming eliminates
the physical removal of chips from the system. This will save time and money, both during
development in the lab, and when updating the software or parameters in the field.
Target device
is the device (microcontroller, PLD, etc…), which is to be in-system
programmed.
Содержание 448PRO2
Страница 7: ...Introduction 7 Introduction...
Страница 12: ...12 Quick Start...
Страница 15: ...Detailed description 15 Detailed description...
Страница 16: ...16 DATAMAN 448PRO2...
Страница 30: ...30 DATAMAN 48PRO2 DATAMAN 48PRO2C...
Страница 46: ...46 DATAMAN 40PRO...
Страница 55: ...Setup 55 Setup...
Страница 60: ...60 Step 8 Installation process will start Step 9 Click Finish button to finish setup...
Страница 64: ...64 Click on Continue Anyway button For Windows Vista Click Install this driver software anyway...
Страница 66: ...66 PG4UW...
Страница 133: ...PG4UWMC 133 PG4UWMC...
Страница 146: ...146 Installation procedure customized...
Страница 151: ...Common notes 151 Common notes...
Страница 165: ...Troubleshooting and warranty 165 Troubleshooting and warranty...