TECHNICAL SPECIFICATIONS
20
UNIQ™
F-Theta Scan Lens
The table below lists the standard F-Theta scan lenses currently available:
F-Theta Scan Lens diameter M39
ƒ
= 160S
ƒ
= 254S
mm
183 ± 5
280 ± 4
mm
189 ± 6
292 ± 5
mm²
100 x 100
140 x 140
F-Theta Scan Lens diameter M85
ƒ
= 100L
ƒ
= 254L
mm
99 ± 3
296 ± 5
mm
134 ± 4
359 ± 6
mm²
50 x 50
180 x 180
WD:
Working Distance
FD:
Fixing Distance
MA:
Marking Area
AB:
Aiming Beam
FB:
Focusing Beam
Figure 7: Marking Area
F-THETA SCAN LENS
Working Distance (WD)
Fixing Distance (FD)
Marking Area (MA)
F-THETA SCAN LENS
Working Distance (WD)
Fixing Distance (FD)
Marking Area (MA)
NOTE: Working Distance is defined as the distance between the center of
the marking area (defined in the focal plane) and the closest mechanical
edge of the F-Theta scan lens. Refer to the following figure.
NOTE: Fixing Distance is defined as the distance between the base of the
scan head and the marking area. Refer to the following figure.
NOTE: For products equipped with 160S, 254S and 100L F-Theta scan
lenses the focus position, defined at the point where the focus beam over-
laps with the aiming beam, is preset at factory.
Содержание UniQ 1150-1X41
Страница 1: ...UniQ PRODUCT REFERENCE GUIDE InfraRed Fiber Laser Marker ...
Страница 8: ...PREFACE viii UNIQ ...
Страница 82: ...TECHNICAL SUPPORT 74 UNIQ ...
Страница 84: ...LABELS 76 UNIQ POSITIONING OF EXTERNAL LABELS Figure 50 External labels location ...
Страница 120: ...RECOVER THE LASER MARKER 112 UNIQ 16 Press FINISH to continue 17 Press YES to continue ...
Страница 124: ...116 UNIQ APPENDIX G MECHANICAL DRAWINGS ...
Страница 125: ...LASER MARKER PRODUCT REFERENCE GUIDE 117 LASER MARKER NOTE Please refer to Datalogic website for detailed drawings ...
Страница 126: ...MECHANICAL DRAWINGS 118 UNIQ ...
Страница 127: ......