CONNECTORS SPECIFICATIONS
PRODUCT REFERENCE GUIDE
25
X1 - Command Box (Laser Control)
Panel connector
Socket Sub-D, 25 pins, female.
Figure 17: Female panel socket Sub-D 25 (front view)
PIN
SIGNAL
TYPE***
DESCRIPTION
X1.1
24V_ENABLE_B
Output power
supply
Auxiliary 24V DC power supply available for EXT_ENABLE_B (max 125mA)
X1.2
EXT_ENABLE_B
Digital Input
Secondary external ENABLE signal:
- HIGH level: contact closed
- LOW level or disconnected: contact opened
X1.3
RESERVED
-
DO NOT CONNECT
X1.4
EXT_24V
Output power
supply
Auxiliary 24V DC power supply available for drive input logical HIGH (max
125mA)
X1.5
EXT_24V
Output power
supply
Auxiliary 24V DC power supply available for drive input logical HIGH (max
125mA)
X1.6
EXT_24V
Output power
supply
Auxiliary 24V DC power supply available for drive input logical HIGH (max
125mA)
X1.7
24V_ENABLE_A
Output power
supply
Auxiliary 24V DC power supply available for EXT_ENABLE_A (max 125mA)
X1.8
EXT_ENABLE_A
Digital Input
Primary external ENABLE signal:
- HIGH level: contact closed
- LOW level or disconnected: contact opened
X1.9
BUSY
Digital Output
This signal is used to know if the current spooler is executing (marking in
progress):
- ON during marking process
X1.10
CONNECTOR_PRES-
ENCE
Digital Input
This signal is used to check the presence of the Command Box connector:
- HIGH level: normal operation
- LOW level or disconnected: laser marker faulty
X1.11
START_MARKING*
Digital Input
This signal is used to start to the marking process when a document or a
sequence is running in AUTO MODE** or WORK MODE**:
- HIGH level pulsed signal start the marking process
X1.12
EXT_KEY
Digital Input
External KEY signal:
- HIGH level: contact closed
- LOW level or disconnected: contact opened
X1.13
STOP_MARKING*
Digital Input
This signal is used to stop the marking process:
- HIGH level pulsed signal stop the marking process
X1.14
RESERVED
-
DO NOT CONNECT
X1.15
RESERVED
-
DO NOT CONNECT
X1.16
RESERVED
-
DO NOT CONNECT
X1.17
END
Digital Output
This signal is used to know if the marking process is finished:
- ON at the end of marking process
X1.18
POWER_ON
Digital Output
This signal is used to know if the laser marker is already warmed up:
- ON when the laser is in STAND_BY or READY state
X1.19
GND
Ground
Ground reference
X1.20
SYSTEM_ALARM
Digital Output
This signal is used to know if the laser marker is in booting up state or in
error state:
- ON during BOOTING UP
- ON in case of system error
Содержание UniQ 1150-1X41
Страница 1: ...UniQ PRODUCT REFERENCE GUIDE InfraRed Fiber Laser Marker ...
Страница 8: ...PREFACE viii UNIQ ...
Страница 82: ...TECHNICAL SUPPORT 74 UNIQ ...
Страница 84: ...LABELS 76 UNIQ POSITIONING OF EXTERNAL LABELS Figure 50 External labels location ...
Страница 120: ...RECOVER THE LASER MARKER 112 UNIQ 16 Press FINISH to continue 17 Press YES to continue ...
Страница 124: ...116 UNIQ APPENDIX G MECHANICAL DRAWINGS ...
Страница 125: ...LASER MARKER PRODUCT REFERENCE GUIDE 117 LASER MARKER NOTE Please refer to Datalogic website for detailed drawings ...
Страница 126: ...MECHANICAL DRAWINGS 118 UNIQ ...
Страница 127: ......