PERFORMANCE LEVEL (PL)
PRODUCT REFERENCE GUIDE
79
Block Diagram
A: Safety Switch
B: Safety Logic
C: UniQ™
Shutter OUT/Enable OUT
connector
Interlock
connector
Safety Logic to UniQ™ details for automatic production line
SAFETY
SWITCH
SAFETY
LOGIC
UniQ™
INPUT
OUTPUT
Shutter OUT/
Enable OUT
connector
Interlock
connector
PLC Safety Diagram
Characteristics of components
DOOR SWITCH:
SAFETY INTERLOCK SWITCH, designed in compliance with the standard
currently in effect IEC60947, EN292, EN60204, EN1088. Two redundant contacts. IP67.
B10d=2000000.
SAFETY LOGIC:
main component SAFETY PLC min. PLd according EN13849-1. Output
type relays, min 10mA. To be installed in an IP54 enclosure.
Conclusion
Safety Function of this example meets the quantitative requirements of PLr = c.