61
RADIATION VIEWING CONDITIONS
The Laser output of marking system is to be considered as a highly collimated and intense monochromatic
light source. Due to these characteristics it can be seen as a “punctiform source” of high luminosity. This
means that its image is then focalized on the Retina in a very small spot with a dangerously high power
density! If the beam becomes divergent and scatters to a non-reflecting screen, then there is an “extended
vision” of the image, with a decisively less dangerous power density. So there are different types of radiation
viewing based on the access to the radiation and consequently different degrees of dangerousness.
DIRECT VIEWING OF THE LASER BEAM
This type of viewing is the most dangerous and can occur at the outlet of the laser aperture after having
removed the lens. It is to be avoided at all costs! No protective goggles represent a valid means against
direct viewing of the beam.
DIRECT VIEWING OF THE BEAM AFTER MIRROR REFLECTION
This may occur by directing the beam on a reflecting surface.
Viewing of a mirror reflected beam from a flat surface is very dangerous and equal to direct viewing.
DIRECT VIEWING OF THE BEAM OUTPUT BY AN OPTICAL FIBER
This happens if an Optical Fiber disconnects from the resonator. Viewing of the beam is dangerous up to a
significant distance. Filters and Goggles do not ensure safety.
DIRECT VIEWING OF THE BEAM AFTER FOCUSING
This occurs if the Laser beam is not extinguished with an opportune absorber at the end of its useful path.
Looking at the beam is dangerous up to a considerable distance. Filters and goggles can ensure safety for
brief exposure, as long as they are the right size and certified.
SCATTERED VIEWING OF THE BEAM AFTER FOCUSING
This is the most frequent viewing, but opportune Filters and Goggles can ensure safety, even for prolonged
exposure.
The Nominal Ocular Hazard Distance (N.O.H.D.) for Ulyxe PL™ is showed in the next paragraph.
WARNING!
Always use goggles with conformity certificate.
Remember that
no goggles can provide prolonged protection from direct radiation!
Содержание Ulyxe PL
Страница 1: ...USER S MANUAL Ulyxe PLTM ...
Страница 27: ...TECHNICAL SPECIFICATIONS 27 2 EXAMPLE OF CONNECTION TO PLC Figure 18 Example of connection to PLC ...
Страница 56: ...56 LABELS LOCATION Figure 44 External labels location ...
Страница 66: ...66 APPENDIX D MECHANICAL DRAWINGS NOTE Please refer to Datalogic website for detailed drawings ...
Страница 68: ...68 ...