6
The
marking
system turns off
when powered on
The marking system goes into
hardware protection mode
because a parameter does not
comply with specifications
Check compliance with the stated specifications
(input voltage, environment temperature, etc.)
Cut off power supply to the Ulyxe PL
™
and wait
30/60 minutes before restarting. Contact
technical assistance if the problem persists
The
marking
system turns off
after turning the
key
The marking system goes into
hardware protection mode due
to a protection in the power
system
Check compliance with the stated specifications
(laser diode temperature and current, etc.) Cut
off power supply to the Ulyxe PL
™
and wait
30/60 minutes before turning it back on. Contact
technical assistance if the problem persists
The marking
system turns off
during regular
operation
The marking system goes into
hardware protection mode due
to a system malfunction
Make sure the Aux interlock connector is present.
Cut off power supply to the Ulyxe PL
™
and turn it
back on
Check compliance with the stated specifications
(input voltage, environment temperature, etc.)
Cut off power supply to the Ulyxe PL
™
externally
and wait 30/60 minutes before restarting. Contact
technical assistance if the problem persists
The USB
connection is not
working
No connection between PC and
Ulyxe PL
™
Make sure the right Ulyxe PL
™
USB driver as
well as the connection cable are present. Please
refer to section “USB
for additional
info
The LCD does not
work
No power on the display
Make sure the marking system is turned on.
Contact technical assistance if the problem
persists
The
marking
system does not
turn on
The input power is not right or
the internal board is broken
Make sure the
Reverse Voltage
back panel LED
is active and exchange the power supply cable
pins because they are reversed. Contact
technical assistance if the problem persists
Laser beam
emitted with shutter
open with no
emission
commands
The internal RF Q-switch may
be damaged or misaligned, or
its RF driver is not working
properly
Check to see if you can solve the problem
decreasing thermalization value on Lighter Suite
laser settings. Contact technical assistance if the
problem persists
The laser beam
and the pointer one
do not move
correctly during
emission
The laser beam galvo mirrors
are not driven correctly due to
internal damage
Contact technical assistance if the problem
persists
Содержание Ulyxe PL
Страница 1: ...USER S MANUAL Ulyxe PLTM ...
Страница 27: ...TECHNICAL SPECIFICATIONS 27 2 EXAMPLE OF CONNECTION TO PLC Figure 18 Example of connection to PLC ...
Страница 56: ...56 LABELS LOCATION Figure 44 External labels location ...
Страница 66: ...66 APPENDIX D MECHANICAL DRAWINGS NOTE Please refer to Datalogic website for detailed drawings ...
Страница 68: ...68 ...