AMT58x-CB CANopen®
39
Enable Cyclic mode
6200-00 Cyclic time
Set cyclic time (100 ms = 64h)
Master
Encoder (Set request)
COB-ID Cmd
Index Sub
Process data
600+ID 2B 00 62 00 64 00 - -
Encoder
Master (Set confirmation)
COB-ID Cmd
Index Sub
Process data
580+ID 60 00 62 00 00 00 - -
Read COB-ID used by PDO1 (
1800 PDO1 parameters
sub 1):
Master
Encoder (Req request)
COB-ID Cmd
Index Sub
Process data
600+ID 40 00
18
01 - - - -
Encoder
Master (Req reply)
COB-ID Cmd
Index Sub
Process data
580+ID 43 00 18 01 B0 B1 B2 B3
COB-ID used by PDO1 = ( (B3<<24) | (B2<<16) | (B1<<8) | B0 )
set the most significant bit to 0:
B3 &= 0x7F;
Set new COB-ID used by PDO1 (
1800 PDO1 parameters
sub 1):
Master
Encoder (Set request)
COB-ID Cmd
Index Sub
Process data
600+ID 23 00 18 01 B0 B1 B2 B3
Encoder
Master (Set confirmation)
COB-ID Cmd
Index Sub
Process data
580+ID 60 00 18 01 00 00 00 00
NOTE
To save new parameters execute the store parameters function (see
object
1010-01 Store parameters
).
When the power is turned off or in case of Reset node and Restore
node commands, parameters not saved are lost.