AMT58x-CB CANopen®
28
1803 PDO4 parameters
PDO4 is used by default for cyclic transmission of the velocity value.
See object
6200-00 Cyclic time
to set the cyclic timer.
01 COB-ID of PDO4 [Unsigned32, rw]
If the node address is set using the internal dip-switches (i.e. at
least one dip-switch for setting the node has HIGH logic level =
1), when the power is turned on, this object is always forced to
the default value. Otherwise, if the node address is set via
software (i.e. all dip-switches for setting the node have LOW logic
level = 0) it retains the set value, unless a software procedure for
setting a new address is forced at power on.
Default = C000 0480h+NodeID (no RTR, COB-ID)
02 Transmission type [Unsigned8, rw]
Default = FEh (cyclic transmission)
NOTE
- Transmission of PDO1, PDO2, PDO3 and PDO4 messages can be
enabled (or disabled) by setting to “0” (or “1”) the most significant bit
(MSB) used by PDO (object
180xh
, sub1).
- Cyclic transmission or synchronous transmission can be modified
by setting the object
180xh
sub 2:
01h: synchronous transmission at each SYNC command;
02h: synchronous transmission after two SYNC commands;
…
FEh: cyclic transmission.
1A00-01 PDO1 mapping parameter
[Unsig32, rw]
This object contains the mapped position value of the encoder
according to DS406 device profile.
Default = 6004 0020h
1A01-01 PDO2 mapping parameter
[Unsig32, rw]
See object
1A00-01 PDO1 mapping parameter
1A02-01 PDO3 mapping parameter
[Unsig32, rw]
See object
1A00-01 PDO1 mapping parameter
1A03-01 PDO4 mapping parameter
[Unsig32, rw]
This object contains the mapped velocity value of the encoder
according to the manufacturer profile.
Default = 3006 0020h