AMT58x-CB CANopen®
9
4.4 Connection cap with M12 connectors
The connection cap has two M12 connectors with pin-out in
compliance with CANopen® standard. Therefore you can use
standard CAN cables commercially available.
M12 connector
A coding
(frontal side)
male
(BUS IN)
female
(BUS OUT)
M12 Description
Case
CAN Shield
1
1
2
+10Vdc +30Vdc Supply
voltage
3
0 Vdc Supply voltage
4 CAN
High
5 CAN
Low
1
CAN Shield is also connected to pin 1 to allow the
connection of the shield even if the plug connector
has a plastic case.
4.5 Connection of the shield
Disentangle and shorten the shielding 1 and then bend it over the
part 2; finally place the ring nut 3 of the connector.
Be sure that the shielding 1 is in tight contact with the ring nut 3.
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: [email protected]