32
3
RS232 Debug connector
The use of this connector is reserved for Service:
5
1
6
9
Figure 39 - RS232 debug connector
RS232 Debug connector pinout
Pin
Name
Function
2
TXD
Transmitted data
3
RXD
Received data
5
GND
Ground
Input Signal Connector
Figure 40 – Input signal connector
Input signal connector pinout
Pin
Name
Function
1
GND
ground reference
13
VS
24 Vdc power out
9
i. u.
internal use
22
i. u.
internal use
2, 14, 15
Refer-
input reference
12
ENC+
encoder input
24
PSAUX+
auxiliary presence sensor
25
PS+
presence sensor
3.3.1 Power
Supply
The input power is supplied to the Lonworks INPUT/OUTPUT connectors (Figure B, 1, 2).
The supply voltage for correct operation of the scanner must be between 20 and 30 VDC.
The max. power consumption is 30 W.
The power block (optional), supplies the power necessary for the DX8200 and allows main
power to be used.
A security system allows the laser to activate only once the motor has reached the correct
rotational speed; consequently, the laser beam is generated after a slight delay from the
power on of the scanner.
The switch (Figure C, 5) on the connector panel turns off power to both the motor and the
laser beams.
During power up of the scanner there is a current peak of about 3A caused by the motor
startup.