2.9.1 Master-slave
The master-slave layout is used to collect data from several scanners to
build a multi-sided reading system; there can be one master and up to 5
slaves connected with the RS485 polled mode on the main serial interface.
The master scanner is also connected to a host computer with the RS232
auxiliary interface.
The P.S. signal is unique to the system; there is a single reading phase and
a single message from the master scanner to the host computer.
In every scanner the jumper block for the selection of the main serial
interface type must be set for RS485 polled (see paragraph 2.4).
In every slave scanner the multidrop address selection must be set within the
range from 0 to 4 max (see paragraph 2.7.2 under "RS485 polled interface").
The DIP switch selections in the master scanner are ignored.
Host
DS41 Master
1
3
2
Main serial interface
1
Auxiliary serial interface
3
Presence sensor
2
DS41 Slave
2
DS41 Slave
2
Figure 2.34 - Master-slave layout
NOTE
The auxiliary serial port of the slave scanners is
only used for configuration.
The termination resistors of the RS485 bus must
not be installed.