TECHNICAL FEATURES
7
SOFTWARE FEATURES
READABLE CODE SYMBOLOGIES
*
EAN/UPC
(including Add-on 2 and Add-on 5
*
Codabar
2/5 Interleaved
*
Code 93
*
Code 39 (Standard and Full ASCII)
*
ABC Codabar
*
Code 128
ISBT 128
*
EAN 128
Pharmacode
*
= ACB Readable. Other symbologies available on request.
Code Selection
up to ten different codes during one reading phase
Decoding Safety
can enable multiple good reads of same code
Headers and Terminators
Up to 128-byte header string
Up to 128-byte terminator string
Operating Modes
On-Line, Serial On-Line, Verifier,
Automatic, Continuous, Test
Configuration Modes
•
Genius™ utility program
•
Genius™ based Host Mode Programming
•
X-PRESS™ Functions
Special Functions
ACB (Advanced Code Builder)
Motor Off
Parameter Storage
Non-volatile internal Flash
ENVIRONMENTAL FEATURES
Operating temperature
(Note 3)
0 to +45
°
C (+32 to +113 °F)
Storage temperature
-20 to +70
°
C (-4 to +158 °F)
Humidity max.
90% non condensing
Vibration resistance
IEC 68-2-6 test FC
14 mm @ 2 to 10 Hz; 1.5 mm @ 13 to 55 Hz;
2 g @ 70 to 200 Hz; 2 hours on each axis
Shock resistance
IEC 68-2-27 test EA
30g; 11 ms; 3 shocks on each axis
Protection class
IP65
PHYSICAL FEATURES
Mechanical dimensions
68 x 84 x 34 mm (2.68 x 3.31 x 1.34 in)
Weight
330 g (11.6 oz)
Note 1:
The features given are typical at a 25
°
C ambient temperature (if not otherwise
indicated).
Note 2:
Further details given in par. 4.3.
Note 3:
If the reader is used in high temperature environments (over 35
°
C), use of the
Beam-shutter is advised (see the Genius™ configuration program).
69
Содержание DS2400N
Страница 1: ...DS2400N REFERENCE MANUAL ...
Страница 5: ...GLOSSARY 70 INDEX 74 v ...
Страница 10: ...x ...
Страница 20: ...DS2400N 1 b Operating mode selection and definition c Digital Outputs configuration 10 ...
Страница 49: ...INSTALLATION 3 Figure 23 ID NET Network Connections with isolated power blocks 39 ...
Страница 50: ...DS2400N 3 Figure 24 ID NET Network Connections with Common Power Branch Network 40 ...
Страница 51: ...INSTALLATION 3 Figure 25 ID NET Network Connections with Common Power Star Network 41 ...